Delete
Repeat Count
Set Enhanced Control
DG2040 Data Generator
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
This Make Sequence menu function deletes the sequence step at the position of
the line pointer.
Operation.
Delete a sequence step
Bottom button
Pop up menu
Make Sequence
Use the general purpose knob to move the cursor to the line where the step is to be inserted.
This Make Sequence menu function sets the block repeat count for the step at the
position of the line pointer.
Operation.
Set the block repeat count for the step
Bottom button
Pop up menu
Make Sequence
Use the general purpose knob to move the cursor to the line where the step is to be inserted.
This Make Sequence menu function sets up the sequence control options that
become valid when the instrument is in enhanced mode. See the SETUP! Run
Mode ! Enhanced for the enhanced operation.
Submenu
Item
Function
Trig Wait
When set to ON, data output stops when the specified sequence
position is reached, and the instrument waits for a trigger input.
Event Jump
When set to ON, if an event occurs during output of the specified line,
control jumps to the set line.
Jump to
Specifies the jump destination (line number) for the Event Jump
function.
Repeat
When Count is selected, that block is repeated the number of times
specified by the Repeat Count setting. When Infinite is selected, the
block is repeated continuously.
Reference
Side button
Delete
Side button
Repeat Count
(set the repeat count)
3 59