6.30.1. Preset Control
6.30.1.1. Dolby Metadata Preset Trigger Source
The Dolby Metadata Preset Trigger Source control allows the user to select where the Dolby Metadata
source is coming from. Below is a description of the available options:
Dolby Decoder A
Dolby Decoder B
External Input 1
VANC Input 1
VANC Input 2
6.30.1.2. Dolby Metadata Present Preset Trigger
The Dolby Metadata Present Preset Trigger is used to trigger presets saved to the module when a
presence of Dolby Metadata is detected. The following selections are available:
None
User Preset 1- 10
Page - 94
When Dolby Decoder A is selected, the metadata from decoder A will be
used to trigger the metadata presets
When Dolby Decoder B is selected, the metadata from decoder B will be
used to trigger the metadata presets
When External Input 1 is selected, the metadata from External Input 1 will be
used to trigger the metadata presets.
When VANC Input 1 is selected, the metadata from VANC Input 1 will be
used to trigger the metadata presets.
When VANC Input 2 is selected, the metadata from VANC Input 2 will be
used to trigger the metadata presets.
When set to None, the module will not trigger a preset on Dolby presence.
When set to User Preset 1 through 10 when the presents of Dolby is
detected the corresponding preset will be applied to the module.
Revision 1.1.1