6.52.1.2. Audio Silence Duration
The amount of time (in seconds) that the audio must remain silent before the audio silence trigger
condition is flagged to be true. The default value is 5.0 seconds with a valid range from 0.5 s to 127.0 s.
6.53. AVM PRESETS
6.53.1. Preset Trigger Conditions
6.53.1.1. Channel X Silence
This option enables/disables the AVM preset trigger conditions. To select a preset trigger condition select
the check box beside the desired condition.
6.53.2. Preset Control
6.53.2.1. AVM Trigger Logic
This option sets the logic to be used when combining the AVM preset trigger conditions to determine if the
overall AVM preset trigger condition if either True or False.
AND
OR
7812UDXD Series 3G/HD Up/Down/Cross Converter with Simultaneous Dual Format Outputs and AES I/O
Figure 6-57: AVM Presets
A value of TRUE, will only happen when all trigger
conditions have been met.
A value of TRUE, will happen when any of the
trigger conditions have been met.