Inputs (Switching functions)

15.6.4
Path:
Parameters
Control voltage on
Emergency stop active
Rapid traverse
Automatic feed
248
The switching functions must not be used as a part of a safety function.
Settings ► Axes ► General settings ► Switching functions ► Inputs
Explanation
Assignment of the digital input for querying the external control
voltage (e.g. for the machine to be controlled)
Default value: Not connected
Assignment of the digital input for querying whether an external-
ly connected emergency stop switch was activated
Default value: Not connected
Assignment of the digital input for a push button that activates
rapid traverse. The rapid traverse is active as long as the push
button is pressed and held.
If rapid traverse is activated, feed rate limitation is ignored by the
feed rate override and the axes traverse at maximum feed rate.
Default value: Not connected
Assignment of the digital input for a push button with the follow-
ing effect:
Manual mode of operation: Pressing the push button
activates automatic feed rate during an axis motion controlled
via the jog keys The axis continues to move until its next
limit switch or until the push button is pressed again. The
automatic feed rate only functions for axes for which limit
switches have also been configured.
MDI mode and Program Run: The push button functions
as an NC START key. Pressing the push button starts and
interrupts the cycles of a program block.
Default value: Not connected