15.6.20 Spindle Axis S - HEIDENHAIN POSITIP 8013 ACTIVE Operating Instructions Manual

Digital readout
Table of Contents

Advertisement

15

15.6.20 Spindle axis S

Path:
Parameters
Axis name
Axis type
Outputs
Inputs
Start-up time for upper spindle
speed range
Start-up time for lower spindle
speed range
Break point of characteristic
curve for start-up times
Minimum spindle speed
Maximum spindle speed for
oriented spindle stop
Maximum spindle speed for
thread cutting
262
Settings ► Axes ► Spindle axis S
Explanation
Definition of the axis name displayed in the position preview
Settings:
Not defined
S
Default setting: S
Definition of the axis type
Settings:
Not defined
Linear axis
Spindle
Default setting: Spindle
Configuration of the Outputs for the spindle
Further information:
"Outputs (S)", Page 263
Configuration of the Inputs for the spindle
Further information:
"Inputs (S)", Page 264
Definition of the required Start-up time until Fmax is reached
Setting range: 50 ms ... 10000 ms
Default value: 500
Definition of the required Start-up time until Fmax is reached
Setting range: 50 ms ... 10000 ms
Default value: 500
Setting of the spindle speed that marks the transition from the
upper to the lower spindle speed range
Setting range: 0 rpm ... 2000 rpm
Default value: 1500
Definition of the minimum spindle speed
Setting range: 0 rpm ... 500 rpm
Default value: 50
Definition of the maximum spindle speed for oriented spindle
stop
Setting range: 0 rpm ... 500 rpm
Default value: 30
Definition of the maximum spindle speed for thread cutting
Setting range: 100 rpm ... 2000 rpm
Default value: 1000
HEIDENHAIN | POSITIP 8013 ACTIVE | Operating Instructions | 01/2018
Settings | Axes

Advertisement

Table of Contents
loading

Table of Contents