15.6.10 Axes X, Y, Z - HEIDENHAIN POSITIP 8013 ACTIVE Operating Instructions Manual

Digital readout
Table of Contents

Advertisement

15

15.6.10 Axes X, Y, Z

Path:
Parameters
Axis name
Axis type
Encoder
Error compensation
Outputs
Inputs
Software limit switches
Start-up time
Kv factor P
252
Settings ► Axes ► X or Y or Z
Explanation
Definition of the axis name displayed in the position preview
Settings:
Not defined
X
Y
Z
Default setting: X, Y, Z
Definition of the axis type
Settings:
Not defined
Linear axis
Spindle
Default setting: Linear axis
Configuration of the connected encoder
Further information:
"Encoder", Page 254
Configuration of the linear error compensation LEC or segment-
ed linear error compensation SLEC
Further information:
"Linear error compensation (LEC)",
Page 257
Further information:
"Segmented linear error compensation
(SLEC)", Page 258
Configuration of the Outputs for the NC function
Further information:
"Outputs", Page 259
Configuration of the Inputs for the NC function
Further information:
"Inputs", Page 260
Configuration of the Software limit switches
Further information:
"Software limit switches", Page 261
Definition of the required Start-up time until Fmax is reached
Setting range: 50 ms ... 10000 ms
Default value: 150
Proportional component of the position controller during
positioning
Setting range: 0.3 m/(min x mm) ... 6 m/(min x mm)
Default value: 2.5
HEIDENHAIN | POSITIP 8013 ACTIVE | Operating Instructions | 01/2018