15

15.6.12 Reference marks (Encoder)

Path:
Parameters
Reference mark
Maximum traverse path
Nominal increment
Reference point displacement
256
Settings ► Axes ► X or Y or Z ► Encoder ► Reference marks
The following parameters depend on the type of encoder connected
and the setting of the reference marks.
Further information:
"Encoder", Page 254
Explanation
Definition of the type of reference mark
Settings:
None: There is no reference mark
One: The encoder has one reference mark
Coded: The encoder has distance-coded reference marks
Default value: One
For linear encoders with coded reference marks:
maximum traverse path for determining the absolute position
Setting range: 0.1 mm ... 10000.0 mm
Default value: 20.0
For angle encoders with coded reference marks:
maximum nominal increment for determining the absolute
position
Setting range: > 0° ... 360°
Default value: 10.0
Configuration of the offset between the reference mark and the
zero point
Further information:
"Reference point displacement",
Page 257