Display
3
Identify button
4
Alarm LED
General boot-up codes
During boot-up or after a hard reset of the SG6000-CN controller, the following occurs:
1. The baseboard management controller (BMC) logs codes for the boot-up sequence, including any errors
that occur.
2. The power button lights up.
3. If any errors occur during boot-up, the alarm LED lights up.
To view the boot-up and error codes, you must access the BMC interface.
Related information
Troubleshoot hardware installation (SG6000)
Configure BMC interface (SG6000)
Power on SG6000-CN controller and verify operation
View boot-up status codes for SG6000 storage controllers
Each storage controller has a seven-segment display that provides status codes as the
controller powers up. The status codes are the same for both the E2800 controller and
the EF570 controller.
About this task
For descriptions of these codes, see the E-Series system monitoring information for you storage controller
type.
Steps
1. During boot-up, monitor progress by viewing the codes shown on the seven-segment display for each
storage controller.
The seven-segment display on each storage controller shows the repeating sequence OS, Sd,
indicate that the controller is performing start-of-day processing.
44
Description
• Blinking or solid blue: Identifies the controller in
the cabinet or rack.
• Off: The controller is not visually identifiable in the
cabinet or rack.
This button can be set to Blink, On (Solid), or Off.
• Amber: An error has occurred.
Note: To view the boot-up and error codes, you
must access the BMC interface.
• Off: No errors are present.