View error codes for SG6000-CN controller
If a hardware error occurs when the SG6000-CN controller is booting up, the BMC logs
an error code. As required, you can view these error codes using the BMC interface, and
then work with technical support to resolve the issue.
What you'll need
• You know how to access the BMC dashboard.
Steps
1. From the BMC dashboard, select BIOS POST Code.
2. Review the information displayed for Current Code and the Previous Code.
If any of the following error codes are shown, work with technical support to resolve the issue.
Code
0x0E
0x0F
0x50
0x51
0x52
0x53
0x54
0x55
0x56
0x57
0x58
0x59
0x5A
Indicates
Microcode not found
Microcode not loaded
Memory initialization error. Invalid memory type or
incompatible memory speed.
Memory initialization error. SPD reading has failed.
Memory initialization error. Invalid memory size or
memory modules do not match.
Memory initialization error. No usable memory
detected.
Unspecified memory initialization error
Memory not installed
Invalid CPU type or speed
CPU mismatch
CPU self-test failed, or possible CPU cache error
CPU micro-code is not found, or micro-code update
failed
Internal CPU error
101

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageGRID SG6000 and is the answer not in the manual?

Questions and answers

Table of Contents