Download Print this page
NetApp SGF6112 Maintenance Procedures
NetApp SGF6112 Maintenance Procedures

NetApp SGF6112 Maintenance Procedures

Storagegrid appliances

Advertisement

Quick Links

Configuration maintenance procedures
StorageGRID Appliances
NetApp
March 14, 2024
This PDF was generated from https://docs.netapp.com/us-en/storagegrid-appliances/sg6100/manage-
drives-tab.html on March 14, 2024. Always check docs.netapp.com for the latest.

Advertisement

loading
Need help?

Need help?

Do you have a question about the SGF6112 and is the answer not in the manual?

Questions and answers

Summary of Contents for NetApp SGF6112

  • Page 1 Configuration maintenance procedures StorageGRID Appliances NetApp March 14, 2024 This PDF was generated from https://docs.netapp.com/us-en/storagegrid-appliances/sg6100/manage- drives-tab.html on March 14, 2024. Always check docs.netapp.com for the latest.
  • Page 2: Table Of Contents

      Turn SGF6112 appliance identify LED on and off ..........
  • Page 3: Configuration Maintenance Procedures

    Use the Manage drives tab You can use the Manage drives tab in the Grid Manager to perform troubleshooting and maintenance tasks on the drives in the SGF6112 appliance. Before you begin • You are signed in to the Grid Manager using a supported web browser.
  • Page 4 Drive details Summary for each drive. Select the appropriate task button, as described in the steps below. Turn locator light on or off To physically locate a drive in the appliance: 1. From the Grid Manager, select NODES > data center. 2.
  • Page 5: Turn Sgf6112 Appliance Identify Led On And Off

    After you fail a drive, you must either physically replace the drive or logically replace the drive. Turn SGF6112 appliance identify LED on and off The blue identify LED on the front and back of the appliance can be turned on to help locate the appliance in a data center.
  • Page 6: Locate Sgf6112 Appliance In Data Center

    4. Turn the identify LEDs on and off as needed. Related information Locate appliance in data center Locate SGF6112 appliance in data center Locate the appliance so that you can perform hardware maintenance or upgrades. Before you begin • You have determined which appliance requires maintenance.
  • Page 7: Power Sgf6112 Appliance Off And On

    Press the identify LED switch on the appliance front panel. Use the appliance BMC interface. Power SGF6112 appliance off and on You can shut down the SGF6112 appliance and power it back on to perform maintenance. Shut down the SGF6112 appliance Shut down the appliance to perform hardware maintenance.
  • Page 8 Power on SGF6112 and verify operation Power on the controller after completing maintenance. Before you begin • You have installed the controller in a cabinet or rack and connected the data and power cables. • You have physically located the controller in the data center.
  • Page 9 Use the BMC interface to monitor start-up status. 3. Confirm that the appliance controller displays in the Grid Manager and with no alerts. It might take up to 20 minutes for the controller to display in the Grid Manager. Don’t take another appliance node offline unless this appliance has a green icon. 4.
  • Page 10: Change Link Configuration Of Sgf6112 Appliance

    View status indicators Change link configuration of SGF6112 appliance You can change the Ethernet link configuration of the appliance including the port bond mode, the network bond mode, and the link speed. Before you begin • You have placed the appliance into maintenance mode.
  • Page 11 ◦ Select Reboot into Maintenance Mode to reboot the compute controller with the node remaining in maintenance mode. (This option is available only when the controller is in maintenance mode.) Select this option if there are additional maintenance operations you need to perform on the node before it rejoins the grid.
  • Page 12 NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp.