6.5.1.1.6 Cable pinout
Warning!
If you wish to assemble a suitable cable yourself, the cable must be wired according to this pinout.
If a field-assembled cable is used, B&R cannot guarantee its functionality. Functionality is only guar-
anteed for the cables available from B&R.
6.5.1.1.7 Wiring
The following information and figure apply if a field-assembled cable is used and connected to an RJ45 network
connector (e.g. patch panel) instead of directly to a B&R device.
The wiring must comply with category 6A (Cat 6A) or 7 (Cat 7) requirements. The maximum total length of 100
m is not permitted to be exceeded.
B&R device
228
Pinout per TIA/EIA 568A
Shield
White (green)
Green
White (orange)
Blue
White (blue)
Orange
White (brown)
Brown
Figure 74: 5CASD3.xxxx-00 - Pinout
Patch panel
Patch cable
Field-assembled cable
Max. 5 m
Max. 100 m
Figure 75: Wiring with a field-assembled cable
Automation PC 3100 User's manual V 1.00 Translation of the original documentation
Patch panel
B&R device
Patch cable
Max. 5 m