2.3.6.2 5AC901.IUPS-00

2.3.6.2.1 General information
UPS IF option 5AC901.IUPS-00 used together with battery unit 5AC901.BUPS-00 allows the B&R industrial PC to
be switched off properly without data loss during a power failure.
UPS interface option 5AC901.IUPS-00 can only be operated in the IF option 1 slot.
Warning!
UPS IF option 5AC901.IUPS-00 is only permitted to be operated with battery unit 5AC901.BUPS-00!
Information:
If the system is in standby mode (S5: soft-off mode or S4: hibernation/suspend-to-disk mode), then the
internal UPS interface option charges the connected battery unit. The system's internal power supplies
are active during this procedure. This allows various actions to be performed (e.g. opening the tray
of the built-in slide-in DVD drive).
2.3.6.2.2 Order data
Model number
Short description
Uninterruptible power supplies
5AC901.IUPS-00
UPS - For 4.5 Ah battery
Required accessories
Uninterruptible power supplies
5AC901.BUPS-00
Battery unit 4.5 Ah - For UPS 5AC901.IUPS-00
5CAUPS.0005-01
UPS cable - 05 m - For 5AC901.IUPS-xx
5CAUPS.0010-01
UPS cable - 1 m - For 5AC901.IUPS-xx
5CAUPS.0013-01
UPS cable - 13 m - For 5AC901.IUPS-xx
5CAUPS.0030-01
UPS cable - 3 m - For 5AC901.IUPS-xx
2.3.6.2.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for this accessory
and may differ from those of the complete system. The data specified for the complete system applies
to the complete system in which this accessory is installed, for example.
Model number
General information
B&R ID code
Certifications
CE
UL
HazLoc
GOST-R
Electrical characteristics
Power consumption
Deep discharge protection
Short circuit protection
Battery charging data
Charging current
Operating conditions
Pollution degree per EN 61131-2
Environmental conditions
Temperature
Operation
Storage
Transport
Automation PC 3100 User's manual V 1.00 Translation of the original documentation
Table 131: 5AC901.IUPS-00 - Order data
Class I, Division 2, Groups ABCD, T3C
Table 132: 5AC901.IUPS-00 - Technical data
Figure
5AC901.IUPS-00
0xD851
Yes
cULus E115267
Industrial control equipment
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
1)
Yes
Max. 30 W at 1 A
Yes
Yes
2)
Typ. 1 A
Pollution degree 2
0 to 55°C
3)
-20 to 60°C
-20 to 60°C
Technical data
105