Technical data

2.2.6.10 LED status indicators

LED status indicators are located on the front of the APC3100.
The following intervals are used for the LED status indicators:
Width of box: 250 ms
Repeat interval: 500 ms. 2 boxes thus correspond to one interval.
LED
Color
Status
Power
Green
On
Blinking
Red
On
Blinking
Red-Green Blinking
Yellow
On
Disk
Yellow
On
Link
Yellow
On
Blinking
Run
Green
Blinking
Green
On
Red
On
Orange
Blinking
42
Power
Disk
Link
Run
Explanation
Power supply OK
The device is started up; the battery state is "BAD".
Information:
For additional information,
see "Battery" on page
43.
The system is in power saving (standby) mode (S5: soft-off
mode or S4: hibernation/suspend-to-disk mode).
The MTCX is running; the battery state is "BAD". The system is in
standby mode (S5: soft-off mode or S4: hibernation/suspend-to-
disk mode).
Faulty or incomplete BIOS, MTCX or I/O FPGA update, battery
state OK, power supply OK
Faulty or incomplete BIOS, MTCX or I/O FPGA update, battery
state OK, power saving (standby) mode (S5: soft-off mode or
S4: hibernate/suspend-to-disk mode)
Faulty or incomplete BIOS, MTCX or I/O FPGA update, battery
state BAD, power supply OK
Faulty or incomplete BIOS, MTCX or I/O FPGA update, battery
state BAD, power saving (standby) mode (S5: soft-off mode or
S4: hibernate/suspend-to-disk mode)
Information:
An update must be performed again.
Power supply not OK. The system is running in UPS mode.
Indicates drive access (HDD, SSD, CFast)
Indicates an active SDL connection on the panel connector.
An active SDL connection was interrupted due to power loss of
the panel.
Information:
Check the power supply or power connection of the
connected panel.
Automation Runtime is starting up.
Controlled by Automation Runtime (ARemb and ARwin).
Application running
Controlled by Automation Runtime (ARemb and ARwin).
Application in service
Controlled by Automation Runtime (ARemb and ARwin).
A license violation has occurred.
Table 31: LED status indicators - Data