2.2.1.2 DVI operation

In DVI operation, all signals needed to operate the Automation Panel are transferred via a separate cable. The
brightness of the display can be set using the brightness buttons.
2.2.1.2.1 DVI operation with single-touch Automation Panel
If an Automation Panel with resistive touch screen (single-touch) is operated with DVI, a DVI, USB type A/B and
RS232 cable must be connected.
Single-touch DVI operation
Power supply
Grounding
Single-touch Automation Panel
with SDL/DVI receiver
Availability of the interfaces on the Automation Panel with SDL/DVI receiver:
Panel In
USB1, USB2
USB 2.0
Maximum cable length: 5 m
Requirements
• Automation Panel with SDL/DVI receiver
• B&R industrial PC with DVI interface
• DVI cable, USB type A/B cable, RS232 cable
2.2.1.2.2 DVI operation with multi-touch Automation Panel
If an Automation Panel with PCT touch screen (multi-touch) is operated with DVI, a DVI and USB type A/B cable
must be connected.
Multi-touch DVI operation
Power supply
Grounding
Multi-touch Automation Panel
with SDL/DVI receiver
Availability of the interfaces on the Automation Panel with SDL/DVI receiver:
Panel In
USB1, USB2
USB 2.0
Maximum cable length: 5 m
Requirements
• Automation Panel with SDL/DVI receiver
• B&R industrial PC with DVI interface
• DVI cable, USB type A/B cable
2.2.1.2.3 General limitations
• Key and LED data is not transferred.
• Service and diagnostic data is not transferred.
• Updating the firmware of Automation Panels is not possible.
• The maximum cable length is limited to 5 m.
Automation PC 3100 User's manual V 1.00 Translation of the original documentation
USB In
USB 2.0
COM interface for touch
screen
USB In
USB 2.0
COM interface for touch
x
screen
DVI cable
USB type A/B cable
RS232 cable
Power supply
Grounding
DVI cable
USB type A/B cable
Power supply
Grounding
Technical data
Power supply
Grounding
Industrial PC
Brightness controls
Power supply
Grounding
Industrial PC
Brightness controls
21

Advertisement

Table of Contents
loading

Table of Contents