B&R Automation PC 3100 User Manual page 156

Hide thumbs Also See for Automation PC 3100:
Table of Contents

Advertisement

Software
Config TDP configurations
BIOS parameter
Configurable TDP
boot mode
1)
Configurable TDP lock
CTDP BIOS control
ConfigTDP Levels
ConfigTDP turbo activation ratio
Power limit 1
Power limit 2
Custom settings nominal
ConfigTDP nominal
Power limit 1
4)
Power limit 2
Power limit 1 time window
ConfigTDP turbo activation ratio
Custom settings down
ConfigTDP level1
Power limit 1
Power limit 2
Power limit 1 time window
Config TDP turbo activation ratio
Table 176: Advanced - Power & Performance - CPU power management control - Config TDP configurations
1)
Thermal design power
2)
Module-specific register
3)
Memory-mapped I/O
4)
For all power limits (PL1 to PL2), the additional description on the display unit must be observed. All values must be entered in mW.
5)
The default value 0 for this table means that pre-programmed default values are used. The system does not use the numeric value 0.
Power limit 3 settings
BIOS parameter
Power limit 3 override
Power limit 3
1)
Power limit 3 time window
Power limit 3 duty cycle
Power limit 3 lock
Table 177: Advanced - Power & Performance - CPU power management control - Power limit 3 settings
1)
The additional description on the display unit must be observed.
2)
The default value 0 for this table means that pre-programmed default values are used. The system does not use the numeric value 0.
4.1.7.2.6.2 GT - Power management control
BIOS parameter
RC6 (render standby)
Maximum GT frequency
Table 178: Advanced - Power & Performance - GT power management control
156
Setting options
Description
Deactivate
Selects the configurable TDP boot mode
Nominal: TDP is not overshot or undershot.
Down
Down: TDP is undershot and the processor works with lower power.
Nominal
Disabled
Disables/Enables TDP control register
Enabled
Disabled
Disables/Enables CTDP BIOS control
Enabled
-
Displays the ConfigTDP levels supported by the MSR
-
Displays the ConfigTDP turbo activation ratio values read by the MSR
-
Displays the PL1 values from MMIO
-
Displays the PL2 values from MMIO
-
Displays the ConfigTDP nominal ratio, turbo activation ratio and PL1 read from the MSR
INT
Defines the PL1 power limit [mW]
Default: 0
Range: 0 to 4095875
5)
Resolution: 125 mW
INT
Defines the PL2 power limit [mW]
Default: 0
Range: 0 to 4095875
Resolution: 125 mW
INT
Defines the PL1 time window [s]
Default: 0
Range: 0 to 128
INT
Defines the ConfigTDP turbo activation ratio
Default: 0
Range: 0 to 255
-
Displays the ConfigTDP nominal ratio, turbo activation ratio and PL1 read from the MSR
INT
Defines the PL1 power limit [mW]
Default: 0
Range: 0 to 4095875
Resolution: 125 mW
INT
Defines the PL2 power limit [mW]
Default: 0
Range: 0 to 4095875
Resolution: 125 mW
INT
Defines the PL1 time window [s]
Default: 0
Range: 0 to 128
INT
Defines the ConfigTDP turbo activation ratio
Default: 0
Range: 0 to 255
Setting options
Description
Disabled
Disables/Enables power limit 3
If the power limit 3 override is disabled, default values are used.
Enabled
INT
Defines power limit 3 [mW]
Default: 0
Range: 0 to 4095875
2)
Resolution: 125 mW
INT
Selects the power limit 3 time window [s]
Default: 0
Range: 0 to 64
INT
Defines the power limit 3 duty cycle [%]
Default: 0
Range: 0 to 100
Resolution: 1
Disabled
Disables/Enables the power limit 3 lock function
Enabled
Setting options
Description
Disabled
Disable/Enables RC6 (render standby)
Permits the GPU to go into standby.
Enabled
Default max frequen-
Maximum graphics frequency (including graphic turbo) [MHz]
cy
The max. possible frequency is selected by default.
Resolution: 50 MHz
100 to 1200 Mhz