B&R Automation PC 3100 User Manual page 27

Hide thumbs Also See for Automation PC 3100:
Table of Contents

Advertisement

2.2.3.1.3 Maximum ambient temperature for typical operation
Information about typical conditions
• The total power of all USB interfaces on the system unit is limited to 4 W.
• 2x Gigabit Ethernet
• No permanent 100% processor utilization and graphics utilization
• The power consumption of the complete system is limited to 25 W. For information about the power con-
sumption of individual components, see
All specifications apply to non-condensing operation.
CFast cards
Graphics options
Interface options
Automation PC 3100 User's manual V 1.00 Translation of the original documentation
2.2.4.2 "Power
All temperature values in degrees
Celsius (°C) at 500 m above sea level, non-condensing
The maximum ambient temperature is typically derated
1°C per 1000 meters starting at 500 m above sea level.
Maximum ambient temperature for typical operation
What can still be operated at max. ambient temperature,
or is there a limitation?
5CFAST.xxxx-00
5CFAST.xxxx-10
5ACCLI02.DPO0-000
5ACCLI02.SDL0-000
5ACCLI02.SD40-000
5AC901.I232-00
5AC901.I485-00
5AC901.ICAN-00
5AC901.ICAN-01
5AC901.IHDA-00
5AC901.IRDY-00
5AC901.IPLK-00
5AC901.ISIO-00
5AC901.ISRM-00
5AC901.IETH-00
5ACCIF02.CANE-000
5ACCIF02.FPLK-000
Table 7: Ambient temperature during operation
calculation".
Technical data
C-3965U
i3-7100U
i5-7300U
i7-7600U
2.2 GHz
2.4 GHz
2.6 GHz
2.8 GHz
60
60
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
27