Ignition Cover; Coperchio Accensione - Rotax Leonardo 120 Workshop Manual

Table of Contents

Advertisement

• In each test, make sure that the polarity of the tester lead is
correct.
I Caution:
Set the tester measuring range either to 1
kW or 20 kW!
Control unit
— "black" tester lead
a
b
a
O
b
O
+
c
O
O
"red" tester
e
O
O
lead
f
X
X
g
O
O
O............ Pointer moves (no significant reading)
X............ pointer does not move

Ignition cover

N Note:
If the pick-up or stator are defective the
complete ignition will have to be replaced.
In general, the system does not require
maintenance and is not subject to wear.
Remove:
• Take out the two Allen screws W to remove the pick-up Q.
• Remove the stator E , after taking out the 3 Allen screws
R.
• Unplug the wire guide block T from its fitting in the ignition
cover.
112 - 2001
c
e
f
g
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
X
O
O
O
2
5
1
3
4
• Ad ogni misurazione fare attenzione alla polarità giusta del
cavo di misurazione dello strumento.
I Attenzione: Predisporre lo strumento al campo di misura
di 1 kW oppure 20 kW!
Centralina
— cavo dello strumento "nero"
a
b
a
O
+
b
O
c
O
O
cavo dello
e
O
O
strumento
f
X
X
"rosso"
g
O
O
O............ Passaggio (la lancetta si muove, valore di misura
senza significato)
X............ non c'è passaggio (la lancetta non si muove)

Coperchio accensione

N Nota:
Se il pick-up o lo statore presenta un
difetto, bisogna sostituire l'accensione
completa. In generale l'impianto non
richiede manutenzione e non è soggetto ad
usura.
Smontaggio:
• Per lo smontaggio del pick-up Q togliere le 2 viti a brugola
W.
• Rimuovere lo statore E dopo aver rimosso 3 viti a brugola
R.
• Togliere il blocco passa-cavi T dall'incastro nel coperchio
accensione.
TYPE 120/154/177
c
e
f
g
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
X
O