19.4.3) Electronic modules
19.4.4) Ignition switches (on-off switch)
Date
Page
1996 05 10
80
See Ill. 4/58.
Ambient temp. for the electronic modules Q: ............. max. 80°C (176°F).
See Ill. 58.
type: two separate, suitable on-off switches
(Ill. 52, pos. L)
switching voltage: min. 250 V
switching current: min. 0,5 A
Feeding lines to on-off switches on the electronic
module (see Ill. 58).
1 each flexible cable 0,75 mm
length approx. 35 mm (1 3/8") beginning at electronic module with one
each plug socket and insulating sleeve 3,96 mm.
NOTE:
One each plug and insulating sleeve are supplied loosely
packed.
shorting cable of top electronic module (marked "A") for ignition circuit A.
Shorting cable of bottom electronic module (marked "B") for ignition circuit
B.
NOTE:
Ignition circuit A controls: top spark plugs of cylinders
Ignition circuit B controls: lower spark plugs of cylinders
ATTENTION: The electromagnetic compatibility (EMC) and electromag-
netic interference (EMI) depends essentially on the shorting
cables used.
Min. section area: 2x 0,75 mm
shielding braid on both ends grounded).
ATTENTION: The metal base of each ignition switch must be grounded to
air craft frame.
Install
914 F
Cyl. 2
Cyl. 4
2
, brown
2
Reference
Ill. 58
Cyl. 1
B
br
Cyl. 3
br
A
(shielded flexible cable,
Modification-No.
- 0 -
1