Bsc Batch Port Parameters; Bsc Batch Port Record, Screen 3 - Cabletron Systems FRM User Manual

Frame relay module for the smartswitch 9000
Hide thumbs Also See for FRM:
Table of Contents

Advertisement

BSC Batch Port Parameters

Configuring BSC Batch
BSC Batch S ubs criber In formation
*
RLP: 0 Port: 1
*
I/O: V.35
A Sq B Local S ub.
C R emote S ub. D A tcl
01
100101000000000
200201000000000 N
02
100101000000001
211020100000000 N
03
100101000000002
212202010000000 N
04
100101000000003
203301000000000 N
05
100101000000004
231020100000000 N
Select
Figure 11-2 BSC Batch Port Record, Screen 3
Table 11-1 BSC Batch Port Parameters
Parameter
Port Type
Physical Por t Interface
Blocked Port Flag
Line Speed
Retr ansmission Per iod
(ms)
Maximum Retr ansmissions
Maximum Bytes per Frame
Generate Clock
Rcv Clock (TT) from DTE
EBCDIC
Tr ansparent Text Suppor ted
Ack
Controller Type
Full Duplex
# of Beginning Sync Chars
# of Trailing Pad Chars
No Response Timer
(sec)
No Response Retry Count
Delay Timer
(sec)
(continued on next page)
Node N ame=nodexyz
E R tytm F Rty#
G Del
60
0
60
0
60
0
60
0
60
0
Valid Values
BSC-B
see explanation
Y/N
1
75 bps – 19.2 Kbps
1–9999
1–99
25–4105
Y/N
2
Y/N
Y/N
Y/N
A–C
A–F
Y/N
2–10
1–10
2–10
4–255
1–10
Default Value
(not valid here)
see explanation
N
9600 bps
2000
5
4105
Y
N
Y
Y
none
none
Y
2
1
2
5
1
11-3