Frame Relay Backup Examples - Cabletron Systems FRM User Manual

Frame relay module for the smartswitch 9000
Hide thumbs Also See for FRM:
Table of Contents

Advertisement

Example 1
Configuring Frame Relay
Example 1
Node 1
Example 2
Node 1
Example 3
Node 1
Figure 7-1 Frame Relay Backup Examples
Connections can be between any two devices in the family FRM/
SmartSwitch 1800/FRX. In an FRM, the primary and backup DLCIs
must be on the same RLP, or a PVC must be configured between the
DLCIs.
In Example 1, the primary link is between Node 1/RLP 1/Port 2/DLCI 16 and Node
2/RLP 0/Port 0/DLCI 18. The DLCIs should be configured as described below. (The
parameters are described later in this chapter.) Then if the primary link goes down, a
connection will automatically be established between Node 1/RLP 1/Port 0/DLCI 17
and Node 2/RLP 0/Port 4/DLCI 17.
On Node 1, configure the following (as well as other parameters necessary for oper-
ation—this section deals only with the frame relay backup function):
1. Port Configuration (
RLP: 1
RLP Port: 2
O Additional Parameters
D Configure DLCI Parameters
DLCI ID: 16
I
DLCI Backup Configuration
A Backup Group Number: 10
B Enable Backup Protocol?: N
E For Backup Use Only: N
1,2,16
1,0,17
RLP,Port,DLCI
1,2,16
1,0,17
1,2,16
1,0,17
from Main Menu) for the primary:
[A], [C], [A]
0,0,18
Node 2
0,4,17
RLP,Port,DLCI
0,0,18
Node 2
Other
Device
0,0,18
Node 2
0,4,17
1,3,22
1,4,56
Other
Device
(or any unused number except
)
0
7-3