Setting Port Status Fields - Cabletron Systems TRMM User Manual

Local management
Hide thumbs Also See for TRMM:
Table of Contents

Advertisement

Possible FNB multiplexer configurations include:
Attached Left (<––––|) – that is, connected via the backplane to the
module on its immediate left, but not to the right.
Attached Right (|–––>) – that is, connected via the backplane to the
module on its immediate right, but not to the left.
Attached Left/Right (<--->) – that is, connected via the backplane to
the modules to its immediate left and right.
Detached Left/Right (|–––|) – that is, disconnected from any module to
its left or right, via the backplane.
Bypassed (<-B ->) - that is, all station ports (and in some instances ring
ports) are bypassed to form a self-contained ring on the module.
However, neighboring MIMs will still be attached via the FNB
backplane. The TRMM and the TRMMIM cannot be bypassed.
Bypassed Right (<-B -|) - that is, the module is bypassed by the module
to its right, but connected to the module to its left.
Bypassed Left (|-B ->) - that is, the module is bypassed by the module
to its left, but connected to module to its right.
To configure the FNB or Bypass MUX:
1. Select the ADMINISTRATIVE mode.
2. Highlight the MUX field for the desired module.
3. Toggle between the possible FNB/BYPASS MUX configurations and
press Enter to execute the change.

5.1.4 Setting Port Status Fields

The Port Status field shows a port's current operational status.
Use the following steps to selectively modify a port's operational status
from the ADMINISTRATIVE mode:
1. Highlight the desired Port Status field.
2. Toggle to a port setting.
THE DEVICE STATUS MENU
1 [ OFF]
1 [ ON]
2 [ OFF]
2 [ ON]