Backup Group Parameters; Frame Relay Backup Group Parameters - Cabletron Systems FRM User Manual

Frame relay module for the smartswitch 9000
Hide thumbs Also See for FRM:
Table of Contents

Advertisement

Backup Group Parameters

RLP
Entry
Port
DLCI
WaitTimer
ProtEnab
Delete?
7-22
Table 7-6 Frame Relay Backup Group Parameters
Parameter
RLP
Entry
Port
DLCI
WaitTimer
ProtEnab
Delete?
1 The port must be on the same RLP as the primary DLCI (the one being backed up), or a
PVC must be configured between the primary and backup DLCIs.
2 The DLCI must have already been created in Port Configuration. Also, a DLCI cannot
be assigned to more than one backup group, nor can it be assigned to a backup group if
it is a primary DLCI (one that will be backed up).
3 See explanation.
identifies the RLP containing the primary and backup DLCIs.
is simply an identifier.
is the physical port on which the backup DLCI is being configured.
is the backup being configured.
is the time after a primary DLCI failure that the software will wait for this DLCI to
become active before checking the next backup DLCI. If the backup does not become
active before the timer expires, the software will search the backup group for the next
available backup.
enables (if
) the backup protocol on the specified DLCI. It should be set to
Y
only if) the remote device is an FRM with the backup protocol enabled on the remote
DLCI connected to this backup group entry.
The remote node must be the same one to which the primary DLCI was connected,
and the remote node's backup DLCI must be on the same RLP as its primary DLCI.
Also, the primary DLCI in the initiating node must have the remote node's primary
RLP/port/DLCI configured in its DLCI parameters.
deletes the entry. When asked to confirm, press
numbers will move up one to fill the gap.
Valid Values
0–2
0–9
1
0–7
2
16–991
0–65535
(seconds)
Y/N
n/a
. Any entries with higher sequence
[Y]
Frame Relay Module 4.0 User Guide, Rev 01
Default Value
0
0
0
16
120
3
N
n/a
if (and
Y