Trap Routing Parameters - Cabletron Systems FRM User Manual

Frame relay module for the smartswitch 9000
Hide thumbs Also See for FRM:
Table of Contents

Advertisement

Trap Routing Parameters

Address
Enabled
Severity
Configuring SNMP
If running IP over a frame relay port with link layer man-
agement (LMI or Annex D), initial IPL traps will be lost by the
time the frame relay DLCI comes up.
Parameter
Address
Enabled
Severity
is an IP address to which all traps meeting the "enabled" and severity class criteria will
be sent.
determines whether or not traps meeting the severity class criterion will be sent to the
specified address.
determines the lowest severity-level traps (events) that will be sent to the specified
address. (1 is the highest.) For example, if 3 is specified, traps of severity levels 1, 2,
and 3 will be sent (assuming the menu item is enabled).
There are four levels of severity:
Level 1 = Serious fault. This is a serious error and immediate action is required.
Level 2 = Major fault/link alarm. Link alarms 400–406 are at this level simply
to show importance; for any other events, take action as soon as possible.
Level 3= Minor fault/traffic disturbance. Clear the fault at the first suitable
occasion.
Level 4 = Configuration error/informational event. Depending on the event, no
action may be necessary and, if so, correcting the configuration of certain
database parameters may be adequate.
Event messages and their severity levels are listed in
Table 16-3 Trap Routing Parameters
Valid Values
valid IP address
Y/N
1–4
Default Value
0.0.0.0
N
4
Chapter
21.
16-5