Port Type
Physical Port Interface
Blocked Port Flag
Configuring Frame Relay
Table 7-4 Frame Relay DLCI Parameters
Parameter
Committed Information Rate (In/Out)
Committed Burst Size (In/Out)
Excess Burst Size (In/Out)
BECN Recovery Count
Outgoing DLCI Pr iority
Backup Group Num ber
Enable Backup Protocol?
5
Remote RLP
5
Remote Port
5
Remote DLCI
5
Switchover Tim er
5
Switchback Timer
Time to Hold Data While Waiting
If rate control will not be used, configure the
1
match the line speed on the port. Otherwise, the DE-bit will be set on all received frames.
CIR = Committed Information Rate. (See first parameter in table.)
2
Applicable only on the initiating node. (See explanation.) If configuring a DLCI that will
3
be backed up, you must leave this value at
Then re-enter Port Configuration on this RLP/port/DLCI and specify the desired group.
A value of
means that the DLCI will not be backed up; therefore, set the Group to
0
the DLCI will be a backup.
Set to
for the initiating backup DLCI and
N
4
Displayed only if
5
If set to
, switchback will not occur unless the backup fails.
65535
6
specifies the protocol the port will support. Selecting this parameter will display a list
of valid protocols. (Protocol configuration is described in
is determined by the Line Interface Card(s) and attached cables. The RLP record iden-
tifies the LIC, and only the valid interfaces will be displayed on the Port screen,
among:
RS-232, V.35, RS-449
is RS-422.)
will cause the port to be enabled (
in that state until this parameter is changed or an on-line enable (
Main Menu) or disable (
If set to
, no backup DLCIs on this port will be used (even if the port is enabled via
Y
on-line port enable).
Valid Values
(Kbits/sec)
0–2000
.08 CIR–16xCIR (in kbits)
{B
/CIR x (linespeed minus
0–
C
1
CIR)}
(packets)
1–255
0–4
3
0–255
4
Y/N
SmartSwitch 1800, FRX4000:
FRM:
0–2
FRX6000:
0–7
SmartSwitch 1800:
Other node type:
16–991
(seconds)
0–65535
(seconds)
0–65535
5
(seconds)
0–65535
until you have configured a backup group.
0
Y
is a value other than
Backup Group Number
, and
.
(RS-449 and X.21 i
X.21
) or disabled (
N
from the Main Menu) is performed.
[B], [B], [A]
Default Value
1
1
0
2
CIR
0
8
0
0
N
0
0
0–3
0–7
0
16
0
6
5
30
Committed Information Rate
for the remote backup DLCI.
.
0
Chapter
5.)
nterfaces are valid if the LIC
) at node IPL. The port will remain
Y
[B], [B], [C]
(CIR) to
if
0
from the
7-15

Advertisement

Table of Contents
loading