Subscriber Parameters; Typical Svc Subscriber Screen - Cabletron Systems FRM User Manual

Frame relay module for the smartswitch 9000
Hide thumbs Also See for FRM:
Table of Contents

Advertisement

Subscriber Parameters

Subscriber Name
11-8
SV C S ubs criber Maintenan ce
* S ubs criber ID
A S ubs criber Name
B R outing A lgorithm
C S ystematic R ed irection
D R ed irect on Busy
E R ed irect on Ou t of Order
F C onnection Priority
G R outing Paths
H R ed irection Add ress es
Option:
Figure 11-3 Typical SVC Subscriber Screen
Pressing
will display routing paths, which link the subscriber with one or more
[G]
ports. Pressing
will display the addresses used for call redirection. (These
[H]
addresses are valid only if
first screen.) Parameters for all three screens are described following Table 11-2.
Parameter
Subscriber Name
Routing Algorithm
System atic Redirection
Redir ect on Busy
Redir ect on Out of Order
Connection Priority
1st, 2nd,etc. Path Configured
RLP
Port
Redir ection Address 0,1,etc.
The software does not verify that the specified port exists. Make sure the specified ports
1
are configured in the database, and that they actually exist.
identifies the subscriber to the console operator. The FRM software does not use this
information.
0100012345
sub 1
0, Roun d R obin
N
N
N
0
[A],[D],[B]
is specified for one or more of items C, D, and E on the
Y
Table 11-2 Subscriber Parameters
Valid Values
0–31 characters
0–3
Y/N
Y/N
Y/N
0–9
Y/N
0–2
Physical port:
Logical port:
valid address
Node N ame=nod exyz
from Main Menu
Default Value
none
0
N
N
N
0
N
0
1
0–7
1
8–63
0
none
Frame Relay Module 4.0 User Guide, Rev 01