Siemens SIMATIC ET 200AL System Manual page 477

Distributed i/o system
Hide thumbs Also See for SIMATIC ET 200AL:
Table of Contents

Advertisement

Technical specifications
6.1 Technical specifications
Article number
Load resistance range
Output voltage
Output current
Switching frequency
Total current of the outputs
Cable length
Encoder
Connectable encoders
Interrupts/diagnostics/status information
Substitute values connectable
Alarms
Diagnoses
Diagnostics indication LED
Potential separation
between the load voltages
Potential separation channels
26
lower limit
upper limit
for signal "1", min.
for signal "1" rated value
for signal "0" residual current, max.
with resistive load, max.
with inductive load, max.
on lamp load, max.
Current per group, max.
unshielded, max.
2-wire sensor
permissible quiescent current (2-wire sen-
sor), max.
Diagnostic alarm
Short-circuit
Channel status display
for module diagnostics
For load voltage monitoring
between the channels, in groups of
between the channels and backplane bus
between the channels and the power supply
of the electronics
Digital input/digital output module DIQ 4+DQ 4x24VDC/0.5A 4xM12 (6ES7143-5AF00-0BA0)
6ES7143-5AF00-0BA0
48 Ω
4 kΩ
L+ (-0.8 V)
0.5 A
0.5 mA
100 Hz
0.5 Hz
1 Hz
2 A
30 m
Yes
1.5 mA
Yes; channel by channel, parameterizable
Yes; Parameterizable
Yes; Outputs to M; encoder supply to M; module
by module
Yes; green LED
Yes; green/red LED
Yes; green LED
Yes
4; DIQ channels are isolated from DQ channels
Yes
No; DIQ channels are non-isolated and DQ chan-
nels are isolated from supply voltage 1L+
Equipment Manual, 08/2021, A5E36683613-AB

Hide quick links:

Advertisement

Table of Contents
loading