Siemens SIMATIC ET 200AL System Manual page 242

Distributed i/o system
Hide thumbs Also See for SIMATIC ET 200AL:
Table of Contents

Advertisement

Connecting
6.1 Connecting BaseUnit BU-Send
Procedure
To connect the BusAdapter BA-Send 1xFC , follow these steps:
1. Strip the sheath of the bus cable at the open end as follows:
Figure 6-3
Use the Stripping Tool for ET-Connection to do this. The relevant settings are shown on
the tool.
2. Pull back the locking slide of the BusAdapter BA-Send 1xFC and open the cover of the
connection element.
3. Lift the cable routing up as far as it will go.
4. Insert the unstripped single cores of the bus cable (according to the imprinted color coding)
into the cable routing as far as they will go and press the cable routing down as far as it will
go.
5. Close the cover of the connection element and push the locking slide forward.
24
Connecting cable
Mixed configuration
Equipment Manual, 11/2020, A5E33344611-AD