Nortel Communication Server 1000S Installation And Configuration Manual page 265

Isdn primary rate interface
Hide thumbs Also See for Communication Server 1000S:
Table of Contents

Advertisement

LD 17 — Adding a D-channel interface (Part 3 of 3)
Prompt
- - T23
- - T200
- - N200
- - N201
- - K
LD 15 — Defining a PRI customer (Part 1 of 3)
Prompt
REQ:
TYPE:
CUST
Response
Description
1-(20)-31
Interface guard timer checks how long the interface takes
to respond. In units of 0.5 seconds
(default 20 = 10 seconds).
2-(3)-40
Retransmission timer in units of 0.5 seconds
(default 3 = 1.5 seconds).
1-(3)-8
Maximum number of retransmissions.
4(260)
Maximum number of octets in information field.
1-(7)-32
Maximum number of outstanding unacknowledged
frames (NAKS).
Response
NEW
CHG
NET
0-99
0-31
ISDN Primary Rate Interface
1.5 Mb PRI implementation
Description
Add new data.
Change existing data.
Networking Data.
Customer number
Range for Large System, Call Server 1000E, and
Media Gateway 1000E
Range for Small System, CS 1000S system,
Media Gateway 1000B, and Media Gateway 1000T
Page 265 of 394
Installation and Configuration

Advertisement

Table of Contents
loading

Table of Contents