Clock Controller description and installation
Figure 65
Example 6, Complex Isolated Private Network
Clocking off Master:
Tracking on Primary loop Y
and loop W used as a
secondary clock source
Small System
LD 60
TRCK FRUN
LD 73:
PREF loop X
SREF loop W
Small System
LD 60
TRCK PCK
LD 73:
PREF <cr>
SREF <cr>
Slave
Tracking on Primary
loop Z, no secondary
clock source
Digital connections to the Central Office do not exist in this example. If it
does, the PBX connected to it will track off the CO and will in turn be used
as a clock source to other nodes.
When a second Digital loop from the Master system becomes available, it can
be used as a Secondary Clock Source in case the Primary Source fails.
ISDN Primary Rate Interface
Master clock
Non-tracking
Small System
loop X
loop Y
Small System
loop Z
Clocking off Master:
Tracking on Primary loop Y,
no secondaryclock source
Installation and Configuration
Page 205 of 394
(Free-run)
LD 60
TRCK FRUN
LD 73:
PREF <cr>
SREF <cr>
loop Y
LD 60
TRCK PCK
LD 73:
PREF loop X
SREF loop Y
Slave
553-AAA0070