Nortel Communication Server 1000S Installation And Configuration Manual page 263

Isdn primary rate interface
Hide thumbs Also See for Communication Server 1000S:
Table of Contents

Advertisement

LD 17— Adding a PRI card
Prompt
Response
REQ
CHG
TYPE
CFN
CEQU
YES
PRI
loop x
card x
TMDI
(Yes)
No
LD 17 — Adding a D-channel interface (Part 1 of 3)
Prompt
REQ
TYPE
- ADAN
- CTYP
Description
Change existing data.
Configuration data block.
Changes to common equipment.
For Large Systems
For Small Systems and CS 1000S Systems
TMDI Card (Mode set to PRI OR TRK) Option 11C Cabinet
Other card
Response
Description
CHG
Change existing data.
ADAN
Action Device And Number.
NEW DCH xx
Add a primary D-channel (any unused SDI port.)
CHG DCH xx
Change a primary D-channel.
OUT DCH xx
Remove the primary D-channel, where:
xx =0-79.
DCHI
DCHI = D-channel configuration for the NTAK09 card or
NTAK93.
MSDL
MSDL = NTBK51 Downloadable D-channel
daughterboard.
TMDI
TMDI = D-channel configuration on TMDI (NTRB21) card.
ISDN Primary Rate Interface
1.5 Mb PRI implementation
Installation and Configuration
Page 263 of 394

Advertisement

Table of Contents
loading

Table of Contents