Nortel Communication Server 1000
ISDN Primary Rate Interface
Installation and Commissioning
NN43001-301
.

Advertisement

Table of Contents
loading

Summary of Contents for Nortel 1000

  • Page 1 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301...
  • Page 2 KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice. Nortel, the Nortel Logo, the Globemark, SL-1, Meridian 1, and Succession are trademarks of Nortel Networks. All other trademarks are the property of their respective owners.
  • Page 3: Table Of Contents

    How to get help Getting help from the Nortel web site 11 Getting help over the telephone from a Nortel Solutions Center 11 Getting help from a specialist by using an Express Routing Code 11 Getting help through a Nortel distributor or reseller 12...
  • Page 4 Port definitions 144 Scenarios for replacement of a digital trunk card (QPC720/QPC472) by a DDP card 144 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 5: Contents

    Software enable the DTI/PRI cards 222 1.5 Mb ISL implementation Contents 227 Overview 227 Hardware requirements 227 Basic ISL implementation 232 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 6 NTND26 PRI to MSDL cables 303 NTND27 MSDL to I/O panel cables 303 NTND98 PRI to I/O panel cables 303 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 7: Procedures

    Implementing dedicated mode 232 Procedure 39 Connecting the cables 240 Procedure Procedure 40 Connecting the cables 264 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 8 Inspecting the NTBK50 circuit card 266 Procedure 42 Installing the NTAK02 286 Procedure 43 Setting up the D-channel 287 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 9: New In This Release

    August 2007 Standard 01.03. This document has been up-issued to support a change request. June 2007 Standard 01.02. This document is up-issued to remove the Nortel Networks Confidential statement. May 2007 Standard 01.01. This document is issued to support Communication Server 1000 Release 5.0.
  • Page 10 (553-3011-315) (Content from 2.0Mb DTI/PRI: Description, Installation and Maintenance (553-3011-315) also appears in ISDN Primary Rate Interface Maintenance (NN43001-717).) Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 11: How To Get Help

    Getting help over the telephone from a Nortel Solutions Center If you do not find the information you require on the Nortel Technical Support web site, and you have a Nortel support contract, you can also get help over the telephone from a Nortel Solutions Center.
  • Page 12: Getting Help Through A Nortel Distributor Or Reseller

    12 How to get help http://www.nortel.com/erc Getting help through a Nortel distributor or reseller If you purchased a service contract for your Nortel product from a distributor or authorized reseller, contact the technical support staff for that distributor or reseller.
  • Page 13: Introduction

    Introduction This document is a global document. Contact your system supplier or your Nortel representative to verify that the hardware and software described are supported in your area. Subject Note on legacy products and releases This technical document contains information about systems, components, and features that are compatible with Nortel Communication Server 1000 Release 5.5 software.
  • Page 14: Intended Audience

    • Software Input Output Reference — Maintenance (NN43001-711) Online To access Nortel documentation online, click the Technical Documentation link under Support & Training on the Nortel home page: www.nortel.com CD-ROM To obtain Nortel documentation on CD-ROM, contact your Nortel customer representative.
  • Page 15: Isdn Primary Rate Interface Equipment Overview

    "NT8D72 PRI2" (page 25) "Power requirements" (page 25) "NT8D72 faceplate" (page 25) "Cable requirements" (page 27) Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 16 "Cable diagrams" (page 69) "Clock" (page 70) "Reference clock errors" (page 71) "Automatic clock recovery" (page 72) Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 17: Introduction

    Note: The NTRB53 Clock Controller cannot be combined with a QPC775 or a QPC471 card in one system Additional hardware is also required for PRI capability and applications. Installation instructions are given in other Nortel publications, or supplied by the manufacturer. This additional hardware includes: •...
  • Page 18: Isdn Signaling Link (Isl) Hardware

    • NT8D72 (AB/BA) PRI2 card • NT5D97 dual-port DTI2/PRI2 card • QPC720 1.5 Mb PRI card Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 19 Smart Modems from power spikes and noisy lines. To increase the reliability on this configuration, use a constant power source when powering the modems. Also, verify that TIE lines meet data grade specifications. Nortel takes no responsibility for ISL D-Channel outages due to modem lockup. •...
  • Page 20: D-Channel Handler Description

    Port J2 is the D-Channel Interface port. Figure 2 "NT6D11 DCH faceplate layout" (page 21) shows the faceplate layout. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 21: Qpc757 Dch

    The QPC757 DCH connects to the QPC720 PRI via a RS-422 cable. The following signals are transmitted across the interface: • RCV DATA Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 22 Signaling feature is configured. The QPC757 vintage D is recommended for combination ISL/PRI networks using NACD or Network Message Services and ISL networks using modems. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 23: Nt6D80 Msdl

    Current Power Heat (VAC) (Watts) (BTUs) (Amps) 3.20 16.00 55.36 0.10 1.20 4.15 0.10 1.20 4.15 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 24 DCE or DTE interfaces. Refer to Figure 4 "NT6D80 MSDL faceplate layout" (page 24). Figure 4 NT6D80 MSDL faceplate layout Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 25: Ntbk51 Downloadable D-Channel Daughterboard

    The NT8D72 contains five LEDs and six external connectors. Figure 5 "NT8D72 PRI faceplate layout" (page 26) shows the faceplate layout. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 26 15-pin male, D-connector External digital trunk 15-pin male, D-connector D-Channel interface 15-pin female, D-connector Echo Canceller/RS-232 interface Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 27 The NT8D72 PRI2 provides an interface to the 2Mb external digital line either directly or through an office repeater, echo canceller or line terminating unit (LTU). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 28 CC-1). One clock controller acts as a back-up to the other. The clock controllers should be completely locked to the reference clock. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 29: Figure 6

    If a clock-controller error is detected, the system switches to the back-up clock controller, without affecting which reference clock is being tracked. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 30: Qpc720 Pri

    The QPC720 PRI uses power and ground from the backplane. This card does not require an intelligent bus. Power requirements are: • +5 volts at 6 amperes Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 31: Table 4

    QPC720 PRI faceplate layout Table 4 QPC720 PRI external connectors Faceplate destination Type 9-pin female, D-connector Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 32: Faceplate Destination

    Canceller detects the length of the loop, then cancels the reflected transmission (callers do not hear their own voices echoed). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 33 Note: The QPC775 Clock Controller is not available in the U.S.A. There can be no mixing of QPC775 and QPC471 in one system. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 34: Disk Drive Hardware

    26 pin female D type connector. The data signals conform to the electrical characteristics of the EIA standard RS-422. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 35 Also shown are the names of the LEDs. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 36 External connectors and LEDs Faceplate Function Designator Type Description Switch ENB/DIS Plastic, ESD protected Card Enable/disable switch Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 37 When the enable/disable switch is in disabled state (lit by hardware). • After power-up, before the card is enabled. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 38 Digital trunk unit 0 recovered clock to primary or secondary reference source on clock controller card 1. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 39 Total_Num_DCH-Units = Num_DCHx1 + Num_DDCHx2 + Num_MSDLx4 Therefore, Total_Num_DCH-Units in any given system is between 0-63. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 40: Procedures

    Note: No additional cabling is required for nB+D configurations. Multiple DDP2 cards and the D-channel are associated through software in LD 17. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 41 D-type 9 pin male) on the DDP2 faceplate to the I/O filter (P2, P3 D-type 9 pin males). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 42 I/O filter panel, connecting the 9 pin I/O filter connector to the 9 pin NCTE connector. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 43 Main Distribution Frame (MDF) (P2, P3 D-type 15-pin males). The NTCK78AA is used for systems not equipped with an I/O filter panel. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 44 TRK port on the DDP2 faceplate (P1, D-type 9 pin male) to the Line Terminating Unit (LTU) (P2, P3, P4, P5 BNC males). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 45 CLK0 or CLK1 ports on the DDP2 faceplate to the primary or secondary source ports on Clock Controller card 0 or 1. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 46 NTCK80AC (35 ft) - DDP2 to MSDL cable • NTCK80AD (50 ft) - DDP2 to MSDL cable Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 47 Refer to "Clock configurations" (page for a description on each available option. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 48 48 ISDN Primary Rate Interface equipment overview Figure 16 DDP2 cable for systems with an I/O panel Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 49 Clock for the NT5D97 Clock operation There are two types of clock operation — tracking mode and free-run mode. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 50 • the primary and secondary references are in local (near end) alarm Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 51 If software is unable to track on the assigned secondary reference clock, it switches to free run. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 52 Ref from P0 on Clk0 Ref from P0 on Clk1 Ref from P1 on Clk0 Ref from P1 on Clk1 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 53 DDP2. Connector Clk0 provides a Ref 1 clock source from Unit 0. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 54 Figure 22 "Clock Controller - Option 4" (page 57). Figure 19 Clock Controller - Option 1 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 55 NT5D97 Dual-port DTI2/PRI2 card 55 Figure 20 Clock Controller - Option 2 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 56 56 ISDN Primary Rate Interface equipment overview Figure 21 Clock Controller - Option 3 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 57: Nt5D12 Dual-Port Dti/Pri

    NT5D12 provides an interface to the 1.5 Mb external digital line either directly or through an office repeater, Line Terminating Unit (LTU), or Channel Service Unit (CSU). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 58 PRI link is not receiving a Remote Alarm Indication from the remote facility PRI link is not in FA3 mode Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 59 Also shown are the names of the LEDs. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 60 60 ISDN Primary Rate Interface equipment overview Figure 23 NT5D12 faceplate - general view Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 61 External connectors and LEDs Faceplate Function Designator Type Description Switch ENB/DIS Plastic, ESD Card Enable/disable switch protected Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 62 After power-up, before the card is enabled • When the ENET port on the card is disabled by software. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 63 Digital trunk port 0 recovered clock to primary or secondary reference source on clock controller card 1. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 64 Total_Num_DCH-Units = Num_DCHIx2 + Num_DDCHx2 + Num_MSDLx4 Therefore, Total_Num_DCH-Units in any given system is between 0-63. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 65: Procedures

    LD 17. Note 2: A detailed discussion of each type of DDP cable listed below follows. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 66 15 pin D-type trunk connector mounted on a small PCB. There are no bantam plugs on the DDP faceplate. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 67 Trunk 1 Transmit Ring J5-6 P1J3-9 P1J2-9 T-PRI1RX Trunk 1 Receive Tip Black J5-7 P1J3-3 P1J2-4 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 68 NTCK46AC (35 ft.) - DDP to DCHI cable • NTCK46AD (50 ft.) - DDP to DCHI cable Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 69 DDP cabling for a system Option with an I/O panel, with the connection between the I/O panel and a Network Channel Terminating Equipment (NCTE). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 70 The secondary reference acts as a back-up to the primary reference. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 71 (The interval of this check can be configured in LD 73.) Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 72 Clock configurations Clock Controllers can be used in a single or a dual CPU system. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 73 Ref from P0 on Clk0 Ref from P0 on Clk1 Ref from P1 on Clk0 Ref from P1 on Clk1 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 74 Connector Clk1 provides a Ref 2 clock source from Port 1. Refer to Figure 34 "Clock Controller - Option 4" (page 78) Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 75 NT5D12 Dual-port DTI/PRI 75 Figure 31 Clock Controller - Option 1 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 76 76 ISDN Primary Rate Interface equipment overview Figure 32 Clock Controller - Option 2 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 77 NT5D12 Dual-port DTI/PRI 77 Figure 33 Clock Controller - Option 3 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 78 78 ISDN Primary Rate Interface equipment overview Figure 34 Clock Controller - Option 4 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 79: Dch Installation

    Circuit Card Reference (NN43001-311). J1 configuration is not described in this technical document. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 80: Set Up The Nt6D11Ab, Nt6D11Ae, Nt6D11Af Dchi

    Table 21 "Protocol selection switch settings" (page 81). Note: The setting must be 1 for ISDN applications. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 81 Emulates Switch setting SW2.1 SW2.2 SW3.1 SW3.2 DPNSS1 NT5K35 ISDN NT6D11 Expanded NT5K75 DPNSS1 Port disabled Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 82 "NT6D11 DCH with ISL low-speed programming jumper settings" (page 83). Figure 36 NT6D11 DCH with ISL high-speed programming jumper settings Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 83 Port 1 is used to select the standard or expanded D-channel addressing mode on the NT6D11AB/AE/AF. Refer to Table 25 "Port 1 mode selection" (page 84). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 84 Table 26 Port address switch settings for ISDN Port Address Switch Setting Half Group No. Device No. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 85: Install The Nt6D11Ab, Nt6D11Ae, Nt6D11Af Dchi

    Figure 36 "NT6D11 DCH with ISL high-speed programming jumper settings" (page 82)). Set faceplate toggle switch to DISABLE. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 86: Remove The Nt6D11Ab, Nt6D11Ae, Nt6D11Af Dch

    Disconnect NT6D11AB, NT6D11AE, NT6D11AF DCHI cables. Remove NT6D11AB, NT6D11AE, NT6D11AF DCHI card. Pack and store the card. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 87: Install The Qpc757 Dch

    Coordinate start-up and verification of the DCHI with the start-up of the PRI. Enable the DCHI card using LD 96, command ENL DCH x. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 88 88 DCH installation —End— Figure 38 QPC757 option and PRI/ISL high-speed programming switch settings Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 89 SW3, and SW4. Table 27 D-channel port address switch settings for PRI Port Address Switch Settings Port Number Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 90: Procedure 4 Remove The Qpc757 Dch

    Set faceplate toggle switch to DISABLE. Disconnect QPC757 DCHI cables. Remove QPC757 DCHI card. Pack and store circuit card. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 91: Ntbk51 Ddch Installation And Removal

    Systems. Use Procedure 5 "Install the NTBK51 on the NT5D97 dual-port DTI2/PRI2 card" (page 92) below. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 92: Remove Ntbk51 Ddch From Nt5D97 Dual-Port Dti2/Pri2 Card

    Remove NTBK51 DDCH from NT5D97 dual-port DTI2/PRI2 card Removal procedures for the NTBK51 DDCH are the same for all Large Systems. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 93: Install Ntbk51 Ddch On Nt5D12 Dual-Port Dti/Pri

    Procedure 7 "Install the NTBK51 DDCH on the NT5D12 dual-port DTI/PRI" (page 94) to install the NTBK51 on the NT5D12 dual-port DTI/PRI card. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 94: Remove Ntbk51 Ddch From Nt5D12 Dual-Port Dti/Pri

    Remove the NTBK51 from the NT5D12 dual-port DTI/PRI card Step Action Disable the faceplate switch on the DDP. Remove the DDP and DDCH. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 95: Msdl Installation For All Systems

    Set the MSDL switch settings to correspond to Table 28 "MSDL switch settings" (page 97), and Figure 40 "MSDL card layout" (page 97). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 96 After 10 minutes unplug the card, reinsert it and if the card still does not flash three times, the card is defective and must be replaced. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 97 Port 0—SW4 Port 0—SW8 RS-232-D RS-422-A DTE RS-422-A DCE Port 1—SW3 Port 1—SW7 RS-232-D RS-422-A DTE Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 98: Replace The Msdl

    If the LED turns on and stays on continuously without flashing three times, the card can be defective. Go to step 11. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 99 After 10 minutes unplug the card and reinsert it. If the red LED does not flash three times, the card is defective and must be replaced. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 100 100 MSDL installation for all systems Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 101: Nt8D72 And Qpc720 Pri Card Installation

    Note 1: Due to physical width, Bus Terminating Units (BTUs) and PRIs cannot fit next to each other on a shelf. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 102: Cable Requirements

    Table 31 "Cable for the QPC720 PRI card for Half and Multi Group systems" (page 117). For the QPC720 on Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 103 118). Figure 41 NT8D72(Half Group cabling) on Half and Single Group systems without an echo canceller Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 104 Figure 42 NT8D72 (Half Group cabling) for Half and Single Group systems, with an echo canceller Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 105 Figure 43 NT8D72 (Single Group cabling) for Half and Single Group systems, without an echo canceller Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 106 Figure 44 NT8D72 (Single Group cabling) for Half and Single Group systems, with an echo canceller Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 107 Cable requirements 107 Figure 45 NT8D72 (Multi Group cabling) for Multi Group systems without an echo canceller Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 108 108 NT8D72 and QPC720 PRI card installation Figure 46 NT8D72 (Multi Group cabling) for Multi Group systems with an echo canceller Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 109 Cable requirements 109 Figure 47 QPC720 (Half Group cabling) for Multi Group systems without an echo canceller Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 110 110 NT8D72 and QPC720 PRI card installation Figure 48 QPC720 (Half Group cabling) for Multi Group systems with an echo canceller Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 111 Cable requirements 111 Figure 49 QPC720 (Single Group cabling) for Multi Group systems without an echo canceller Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 112 112 NT8D72 and QPC720 PRI card installation Figure 50 QPC720 (Single Group cabling) for Multi Group systems with an echo canceller Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 113 Cable requirements 113 Figure 51 QPC720 Multi Group cabling without an echo canceller Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 114 Cable for the NT8D72 PRI card for Half and Single Group systems Cable From NTND26 PRI card MSDL Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 115 Note: No additional cabling is required for multiple PRIs. The D-channel is associated through software in LD 17 (prompt PRI). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 116 Note 8: No additional cabling is required for multiple PRIs. The D-channel is associated through software in LD17, prompt PRI. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 117 NT8D79xx QPC775 secondary clock source. QCAD125 QPC471/ CC-0 QPC471/ CC-1 Clock controller NT8D75xx QPC775 QPC775 back-up. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 118 NT8D79xx secondary clock QCP77 source QCAD130 QPC720 QPC47 CC-1 Only when NT8D79xx primary clock QCP77 source Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 119 Echo Run via cabinet Canceller I/O panel to Echo Canceller or crossconnect terminal from non-shielded system Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 120: Switch Settings

    Transmission equalization switch settings for the NT8D72 and QPC720 PRI cards for Large Systems. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 121 NT8D72AA, NT8D72AB, NT8D72BA PRI DIP switch settings for Large Systems Note: For EuroISDN applications, use the default setting (120 ohms). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 122 Note 3: For the DTI with ESF option, you must set the framing format as ESF with the DLOP prompt in LD17 before you set SW3-1 on the card. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 123: Install Nt8D72 And Qpc720 Pri Cards On Large Systems

    Install the network circuit card (if no network loop connection is available). If required, install I/O adapters in the I/O panel. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 124: Remove Nt8D72 And Qpc720 Pri Cards From Large Systems

    DO NOT remove the network card. Pack and store circuit card. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 125: Install An Additional Network Shelf

    C11. Plug the C11 or C21 connector into the single-ended connector of the QCAD172A power cable. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 126 C19 power connection cable to the left rear Network shelf Install PRI trunks and enter related shelf and PRI office data into switch memory. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 127: Nt5D97 Dual-Port Dti2/Pri2 Installation And Removal

    Each NT5D97 card requires one slot on a shelf. NT5D97 cards can be placed in any card slot in the network bus. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 128: Port Definitions

    In this case, the QPC414 should not be removed. The digital trunk is removed and the DDP2 card is plugged into one of the two empty slots. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 129: Nt5D97Aa/Ab Dip Switch Settings

    Ring Ground MSDL Tx Mode LBO Setting Receiver Interface General Purpose Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 130 DIP switches for NT5D97AA/AB The following parameters are set by DIP switches. The boldface font shows the factory setup. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 131 Note: Do not change this setup. Table 40 Trunk interface line build out switch settings Description Switch setting S5/S11 S6/S12 S7/S13 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 132: Table 41

    NTBK51AA D-channel daughterboard and an external DCHI/MSDL. The NT5D97 detects when the onboard NTBK51AA D-channel daughterboard is used. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 133: Table 43

    Device Addresses are equivalent to the MSDL DNUM designations. Note 2: Device address 0 is commonly assigned to the System TTYD Monitor. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 134: Nt5D97Ad Dip Switch Settings

    General Purpose Refer to DIP switch locations in Figure 56 "Dip switches locations for NT5D97AD" (page 135). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 135 Dip switches locations for NT5D97AD The following parameters are set by DIP switches. The boldface font shows the factory setup. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 136: Off - 120 Ohm

    Switch S6 selects the Receiver interface as in Table 49 "Receiver interface switches for NT5D97AD" (page 137). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 137 S8_1-10 can be set to OFF position as in Table 52 "NTBK51AA DCH switches for NT5D97AD" (page 138). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 138 Table 54 Switch setting for MSDL external card Switch Setting DNUM (LD 17) Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 139: Install The Nt5D97 Ddp2

    If required, install the I/O adapters in the I/O panel. Run and connect the NT5D97 cables Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 140: Remove The Nt5D97 Ddp2

    Failure to wear the bracelet can result in damage to the circuit cards. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 141: Configure The Nt5D97 Ddp2

    After the NT5D97 DDP2 is installed, configure the system using the same procedures as the standard NT8D72BA PRI2. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 142 When configuring the NT5D97 DDP2 in DTI2 outgoing dial pulse mode, a Digit Outpulsing patch is required. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 143: Nt5D12 Dual-Port Dti/Pri Card Installation

    Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 144: Port Definitions

    QPC414 card. The other QPC414 card can then be replaced by the NT5D12 DDP. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 145: Nt5D12 Switch Settings

    A per-trunk switch provides selection for T1 transmission. See Table 56 "Trunk interface transmission mode switch settings" (page 146). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 146 A set of four DIP switches selects which Ring lines are connected to the ground. See Table 59 "Ring ground switch settings" (page 147). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 147 External DCH or OFF - MSDL or DCHI card Onboard DDCH ON - Onboard DDCH daughterboard Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 148 Note 1: The Device Addresses are equivalent to the MSDL DNUM designations. Note 2: Device address 0 is commonly assigned to the System Monitor. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 149 NT5D12 switch settings 149 Figure 57 Switch functional areas on the NT5D12 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 150: Install The Nt5D12 Ddp

    Failure to wear the bracelet can result in damage to the circuit cards. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 151: Procedure 16 Install The Nt5D12 On Large Systems

    If required, install connecting blocks at the MDF or wall mounted crossconnect terminal. If required, designate connecting blocks at the MDF or wall mounted crossconnect terminal. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 152: Remove The Nt5D12 Ddp

    Remove cross connections at the MDF to wall-mounted crossconnect terminal. Tag and disconnect cables from card. Rearrange Clock Controller cables if required. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 153: Configure The Nt5D12 Ddp

    You cannot define one of the NT5D12 loops for the NTBK51AA DDCH, and the other loop for the QPC757 DCHI or the NT6D80 MSDL. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 154 154 NT5D12 Dual-port DTI/PRI card installation Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 155: Clock Controller Description And Installation

    "Upgrade to an NTRB53 Clock Controller on a Single Group and Multi Group System" (page 175) Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 156: Introduction

    In general, accurate timing is very important, but more importantly synchronized timing is a must for reliable data transfer. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 157 FDL (Force Download) when enabling the card. At the prompt, enter: Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 158 This statement is true unless the system is used as a Master in an independent/private network (no digital links to a higher Node Category). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 159 4 requirements. Also shown are ways of providing a Secondary Clock Source while preventing timing loops. Figure 59 Hierarchical Synchronization Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 160 (emptied), eventually the buffer runs dry or underflows. This is also a slip-frame repetition. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 161 Ensure all CO/PBX links used as clock references have a traceable path back to the same stratum 1 clock source. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 162 PBX, not the CO. When a second Digital loop is available, it can be used as a Secondary Clock source in case the Primary Source fails. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 163 Secondary Clock Source in case the Primary Source fails. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 164 Secondary Clock Source (SREF= <cr>). In this example, this is illustrated by the node which supports loops X and Z. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 165 Central Offices going down at the same time are minimal. All Central Offices must have a path back to the same stratum 1 source. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 166 When a second Digital loop from the Master system becomes available, it can be used as a Secondary Clock Source in case the Primary Source fails. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 167 The secondary reference acts as a back-up to the primary reference. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 168: Installation Procedures

    Table 64 "Clock Controller shelves and slots" (page 169) shows the systems, the shelves and available slots. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 169 Note: FNF based-systems the total clock path length is equal to the length of the NTRC49 cable used to connect between the two clock controller cards. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 170 71, 81, 81C = On Single group = 61, 61C, 81C = 15-20 ft 21-33 ft 34-50 ft Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 171: Procedure 18 Install A Clock Controller For Half Group And Single Group Systems

    Controller switch settings for QPC775" (page 170), or Table 67 "Clock Controller switch settings for NTRB53" (page 170). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 172 Track on a primary or secondary reference clock, use LD 60. Use the following command: Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 173: Procedure 19 Install A Clock Controller On A Single Group And Multi Group System

    Note 1: Do not disable an active clock or a clock associated with an active CPU. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 174 Note: This allows a smooth transition of the clock controller upgrade. Repeat for the second clock controller, if necessary. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 175: Procedure 20 Remove Old Equipment

    Disable the clock controller card you are removing. At the prompt, enter: DIS CC x Disable system clock controller where x = 0 or 1 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 176: Procedure 21 Installing New Equipment

    **** Exit the overlay Switch to the core with the new clock. At the prompt, enter: Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 177 Set the option switches on the replacement card (NTRB53). Refer to Table 67 "Clock Controller switch settings for NTRB53" (page 170). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 178 Get status of system clock, where x = 0 or 1 **** Exit the overlay —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 179: Isl Installation

    D-channel communicates with the far end using a dedicated leased line, dialup modem, or DTI trunk. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 180: Dchi Switch Settings

    ISL low-speed programming jumper settings for the NT6D11AB, NT6D11AE/AF DCHI. Figure 67 NT6D11AB, NT6D11AD DCHI with ISL high-speed programming jumper settings Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 181: Msdl Switch Settings

    External clock (in LD17) provided by modem, ADM, or ASIM, HSDM: otherwise, DCH runs at 64 Kbps. Refer to Figure 69 "MSDL/ISL settings" (page 182). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 182 In the shared mode, the DCH can share signaling for no more than 382 (T1) or 480 (E1) trunks, including digital and analog. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 183: Dedicated Mode Using Leased Line

    Both modems should be set in the synchronous mode. Figure 71 ISL dedicated mode, using leased line Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 184: Dedicated Mode Using Dialup Modem

    (or the terminating modem). The Hayes Smartmodem User Guide contains explanations of the parameters used in Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 185 B1 E0 L2 M1 Q1 V1 X4 Y0 &C1 &D2 &G0 &J0 &L0 &P0 &Q1 &R0 &S1 &X2 S00:001 S14:ACH S18:000 S21:70H S22:76H S23:17H S25:005 S26:001 S27:61H Stored profile 1: Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 186 DN is dialed by the system. If the call cannot be established, the system continues to dial the hot line number continuously until the call is connected. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 187 To increase the reliability on this configuration, a constant power source can be used when powering the modems. Also ensure that the TIE lines meet data grade specifications. Note 2: Nortel takes no responsibility for ISL D-channel outages due to modem lockup. Figure 74...
  • Page 188 Loopback, Off Note 1: Set only one side of the interface to originate the hot line. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 189: Procedure 22 Install Isl In Dedicated Mode

    Install ISL in shared mode Step Action In LD14, remove the PRI trunks. In LD17, configure ISL for dedicated mode. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 190 In LD16 build another route data block to correspond to the IAS routes. In LD14, assign trunks to the newly configured routes. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 191: Echo Canceller Installation

    Each of the 24 channels on the echo canceller must be initialized as shown here: • Bypass: OFF • Off-hook: ON Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 192: Pri To Echo Canceller Pin Assignments

    EMI. In order to accomplish this, the SDI cables must exit the cabinet through EMI filters on the I/O panel. This procedure depends on the system cabinet type. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 193 Electromagnetic Interference 193 Figure 75 PRI to echo canceller cabling Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 194 194 Echo canceller installation Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 195: 1.5 Mb Pri Implementation

    Table 71 Required circuit cards Circuit card Description NTRB21 DTI/PRI TMDI card. NTAK09 DTI/PRI circuit card. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 196: Hardware Description

    One CSU is required per PRI. Suitable CSUs which support 64 Kbps clear and Bipolar 8 Zero Substitution (B8ZS) are available from vendors such as Verilink, Digitalink, Kentrox, and Tellabs. Note: Contact your Nortel Sales representative for specific local CSU requirements. Hardware description...
  • Page 197 NTRB21, NTAK09, and NTAK20" (page 202). The Media Gateway Expansion does not support digital trunks (DTI/PRI). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 198 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 199 If a Small System is equipped with digital trunks, it is recommended that at least one digital trunk be placed in the main cabinet. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 200 However, if slips are occurring, there is a problem with the clock controller or the incoming line. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 201 If none exist, then this state is acceptable, and the flashing is identifying jitter on the reference. NTAK20 is not equipped. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 202 PRI link connects to the same end location, a single DCHI circuit card can support up to a maximum of sixteen PRI connections for the Small System. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 203: Install Pri Hardware

    "NTAK20 daughterboard installation on the NTRB21" (page 204)) with the tops of the standoffs on the NTRB21. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 204 NTAK20" (page 202) to determine the slot assignment for the NTRB21 TMDI circuit card appropriate to the system. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 205: Procedure 25 Inserting The Ntrb21 Tmdi Card

    The system response is: DCH N EST OPER This means that the D-channel is established and operational. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 206: Procedure 26 Removing The Ntrb21 Tmdi Card

    From an overhead view, with the daughterboard parallel above the NTAK09 and the connector pins aligned over the connector Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 207: Procedure 28 Removing The Daughterboards From The Ntak09

    At least one NTAK20 (per system) is always required. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 208 133 - 266 feet 266 - 399 feet 399 - 533 feet 533 - 655 feet Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 209: Procedure 29 Installing The Ntak09

    NTAK09 circuit card is installed. Connect the other end of the cable to the CSU or DSX-1 cross connect. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 210: Procedure 31 Enabling The Ntrb21 Tmdi Card

    The system response is: DCH N EST OPER This means that the D-channel is established and operational. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 211: Procedure 32 Enabling The Ntak09 Dti/Pri Card

    PRI between systems. No feature applications other than Basic Call Service are included in the implementation. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 212: Procedure 33 Implementing Basic Pri

    For Large Systems and Small Systems TMDI (Yes) TMDI Card (Mode set to PRI OR TRK) Option 11C Cabinet Other card Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 213 Allow or disallow overlap receiving on a D-channel. Default is NO. Enter carriage return if settings are to be left at default. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 214 If a NARS call type is not entered here, it is defaulted to AC1. E.164 National. INTL E.164 Subscriber. International. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 215 1.5 Mb PRI. Prompted only if PRA = YES in LD15. ISDN ISDN option. - MODE Route used for PRA only. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 216 NEW XX. TYPE TIE Trunk only, allowed between MSL-1. l ch Loop and channel for digital trunks Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 217 CCAR 0-(15) Clock Controller Audit Rate. Enter the time (in minutes) between normal CC audits. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 218 218 1.5 Mb PRI implementation Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 219: 1.5 Mb Dti Implementation

    • implementation procedures for basic call service This chapter covers the most common type of Nortel DTI installation – a 24-channel Digital Trunk Interface (DTI) installation between two systems, or between a system and a central office.
  • Page 220: Hardware Description

    DTI. Suitable CSUs which support 64 Kbps clear and Bipolar 8 Zero Substitution (B8ZS) are available from vendors such as Verilink, Digitalink, Kentrox and Tellabs. Contact your Nortel Sales representative for specific local CSU requirements. Hardware description Refer to "Hardware description"...
  • Page 221 49 pin 3 receive tip from network pin 24 pin 11 receive ring from network Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 222: Software Enable The Dti/Pri Cards

    Step Action Enter the following command in LD 60 to software enable all NTAK09 DTI/PRI cards: Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 223: Procedure 36 Implementing Dti

    "LD 16 - Configuring a DTI trunk route" (page 224). Configure the trunks. See "LD 14 - Configuring the trunks" (page 225). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 224 Description Add new data. Change existing data. TYPE Route data block. TKTP Create a trunk route. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 225 Card number for Clock Controller 3. PREF CC3 Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the primary clock reference. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 226 SREF CC4 Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the primary clock reference. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 227: 1.5 Mb Isl Implementation

    Two modes of ISL are available: shared and dedicated. This chapter covers the most common type of Nortel ISL installation, an ISDN Signaling Link (ISL) installation in dedicated mode using dedicated and leased lines.
  • Page 228 ISL in dedicated mode using leased line Using dialup modems The requirements for using a dialup modem are: Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 229 "1.5 Mb PRI implementation" (page 195), with the addition of analog or digital TIE Trunks or both. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 230: Procedure 37 Installing Isl Hardware

    — — Unit 1 C - B B - A C - B B - A Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 231 The far-end modem must be configured for auto-answer. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 232: Basic Isl Implementation

    Card slot in which the card supporting the DCHI 31-39 41-49 resides. PORT Must be set to 1. D-channel for ISDN PRI only. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 233: Nortel Communication Server

    LD 73 - Configuring the D-channel for ISL Prompt Response Description NEW CHG Add new data. Change existing data. TYPE Digital data block. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 234 Coordinated Dialing Plan (CDP). The LSC prompt is required for Calling Line I.D. and Network ACD. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 235 Insert Access Code. Permits the NARS AC1 or AC2 access code to be reinserted automatically on an incoming ESN call. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 236 Prompt Response Description CHID 1-192 Channel identifier for ISL channels. Must be coordinated with the far-end. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 237: 2.0 Mb Dti Implementation

    – 6.15 m length) • CEPT Cable – NTBK05CA (75 coaxial – 6.15 m length) Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 238: Ntak10 2.0 Mb Dti Card

    Each Media Gateway that has a digital trunk must have a clock controller set to an external reference clock. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 239 . Coaxial cable is usually associated with the 75 setting. Table 85 Switch S2 Switch Off (Up) On (Down) S2-1 S2-2 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 240: Procedure 39 Connecting The Cables

    MDF cables. Connect the NTBK05DA/CA interface cable to the 50-pin Amphenol connector Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 241: Dti Software Implementation

    The following procedure describes the process required to program basic 2.0 Mb DTI on the system main and IP expansion cabinets or Media Gateway. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 242: Task Summary List

    FALT(R) abcd (Receive) bits. 2.0 Mb DTI out-of-service. If FALT (receive) signal not required. Incoming Calls: Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 243 Time of RRC(S) signal in milliseconds. P BURS(S) abcd Bring up receiver (send). Uses switchhook flash timer for timer. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 244 Centralized Attendant signal (send) pulse. Pulse time not variable. Note: Prompted for 2.0 Mb DTI only. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 245 If BURS(S) not required. P BURS(R) abcd Bring up receiver (receive) for L1 networking. If BURS(R) not required. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 246 Add or change Digital Trunk Interface data block. TYPE DTI2 2.0 Mb DTI. FEAT Request the digital pad feature. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 247 The receiving pad code is r and the transmission pad code is t. These entries have the range 0-15. The pad values (in decibels) relating to these codes are shown after this table. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 248 The following pads are available for the 2.0 Mb DTI card. Their respective codes are also given. Positive dB represents loss and negative dB represents gain. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 249 Maximum time METR signal is in milliseconds. SASU 0-(1920)-8064 Seize acknowledge supervision period in milliseconds. 2.0 Mb DTI default = 1920 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 250 = time in minutes where nnn = 1-240 • nnH = time in hours where nn = 1-24 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 251 = No new calls threshold time (NNC). ot = Out of service threshold time (OOS). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 252 Card number of PRI/DTI/SILC containing the primary clock reference for the main cabinet Card number for Clock Controller 1. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 253 Add or Change Route data block. TYPE Route data block. CUST Customer number, as defined in LD 15 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 254 Outgoing digit(s) to be absorbed. INST (0)-999 Digits to be inserted. CNTL (NO) YES Changes to controls or timers. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 255 Mb Gateway feature is equipped. For 2 to 16, the pad category used must already be defined in LD 73. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 256 Note: If DIP option is selected, a new SLCA table must be defined in LD 73. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 257: 2.0 Mb Pri Implementation

    Supports the NTAK20 clock controller daughterboard and a D-channel handler interface daughterboard (NTAK93 DCHI or NTBK51 DDCH). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 258: Hardware Description

    NTBK51 D-channel daughterboard, can download software onto the card. This feature is based on the MSDL platform and Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 259 • NTAK20 clock controller daughterboard • NTAK93 D-channel handler daughterboard, or NTBK51 Downloadable D-channel daughterboard. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 260 Every Small System cabinet or Media Gateway that contains a digital trunk must contain a clock controller. If a Small System is equipped with digital trunks, Nortel recommends that at least one digital trunk is placed in the Small System main cabinet.
  • Page 261: Install The Ntak79 Pri Card

    11-19, 21-29, 31-39, 41-49 of the first, second, third, and fourth Expansion cabinets, respectively. Connect the cables. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 262 Figure 83 NTAK79 with switch locations Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 263 (FGND) to the coaxial carrier cable shield, creating a 75 unbalanced configuration. This applies only to the NTBK05CA cable. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 264: Procedure 40 Connecting The Cables

    NTAK79 is installed. reinstall the retaining bar to secure the cable(s) in place. Terminate the NTBK05DA/CA carrier cable as required. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 265: Nortel Communication Server

    — — pin 23 Inner conductor — — pin 48 outer conductor Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 266: Install The Ntbk50 Pri Card

    Inspect the circuit cards for any visible damage that occurred during shipping. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 267 DCHI. It is only used if an NTAK93 D-channel handler daughterboard is being used. It has no effect when using the NTBK51 DDCH daughterboard. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 268 Install the NTAK93 or NTBK51 daughterboard before the NTAK20 daughterboard. Work on a flat surface when mounting or removing daughterboards. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 269 Then press down on the two corners on the opposite side until they lock into place. —End— Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 270 3. To remove the connector pins, grasp the edge of the board adjacent to the connector and lift gently. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 271 Terminate the NTBK05DA/CA carrier cable as required. Figure 87 NTBK50 cabling NTBK05DA pinouts The pinouts for the NTBK05DA cable are as follows: Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 272: Pri Software Implementation

    Note: Before installing PRI cards in IP expansion cabinets or Media Gateway systems, configure them for IP connectivity. Refer to LD 117 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 273 LD 17 - Adding a DCHI or DDCH Prompt Response Description Change data. TYPE Configuration data block. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 274 Prompted only if IFC is set to SL1. NET = network, the controlling switch USR = slave to the controller Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 275 E.164 National. E.164 Subscriber. INTL International. Special Number. Location Code. ISDN Customer is equipped with ISDN. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 276 This prompt only appears on a TIE route and is set to "YES" for features such as Network ACD to function. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 277 Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the primary clock reference. Card number for Clock Controller 3. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 278 16 to obtain the actual count, giving an actual count range of 16-4080. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 279 No New Calls Guard time Group 2, default = 15S. OSG2 nnnS Out Of Service Guard time Group 2, default = 15S. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 280 2.0 Mb PRI trunk. Prompted only if the 1.5/2.0 Mb Gateway feature is equipped and TYPE=2.0 Mb PRI. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 281 11-19 (IP expansion cabinet 1), 21-29 (IP expansion cabinet 2), 31-39 (IP expansion cabinet 3), 41-49 (IP expansion cabinet 4). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 282 282 2.0 Mb PRI implementation Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 283: 2.0 Mb Isl Implementation

    ISL hardware requirements ISL, regardless of the operation mode, uses analog or digital TIE lines as B-channels. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 284 — must support leased line (also known as private line or point-to-point) operation • NTAK19BA 4-Port SDI Cable Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 285 — programmable so that one modem originates the call while the other auto-answers • NTAK19BA 4-port SDI cable. • NT8D09 500 set line card. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 286: Isl Hardware Installation

    Install the NTAK19BA four port cable on the 50-pin Amphenol connector associated with the slot holding the NTAK02. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 287: Procedure 43 Setting Up The D-Channel

    Modems must support leased line capability and synchronous mode. The Hayes Smartmodem 2400 cannot be used on leased lines. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 288: Isl Software Implementation

    Prompt Response Description CHID 1-240 Channel identifier for ISL channels. Must be coordinated with the far-end. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 289 MSDL application small system Card number 1-50 DCHI small system Card number PORT Must be set to 1. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 290 Retransmission timer in units of 0.5 seconds (default 3 = 1.5 seconds). N200 1-(3)-8 Maximum number of retransmissions. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 291 1. E.164 National. E.164 Subscriber. INTL International. Special Number. Location Code. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 292 RTMB Route number and Member number 0-511 1-4000 Range for Large System and CS 1000E system. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 293 Channel identifier for ISL channels (remove with Xnn). Must be coordinated with far-end (no default value). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 294 294 2.0 Mb ISL implementation Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 295: Nonstandard Cables

    "NT9J93AD PRI/DTI Echo Canceller to I/O cable" (page 303) "NTND26 PRI to MSDL cables" (page 303) Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 296: Introduction

    Construction - 24 AWG, stranded foil-shielded twisted pairs • P1 Connector (Pack end) - 9-pin, male, subminiature D, with jackscrews Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 297: Qcad128

    P1-6 P2-6 P1-7 P2-7 P1-8 P2-8 P1-9 P2-9 XRING (transmit ring) to telephone company P1-10 P2-10 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 298: Qcad129

    I/O filter to the Network Channel Terminating Equipment (NCTE) telephone company interface. See Table Table 111 "QCAD133 wire list" (page 299). Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 299: Nt8D7205

    Table 112 NT8D7205 wire list From Color (pack end) (I/O end) Signal White P1-6 P2-6 XTIP (transmit) Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 300: Qcad328

    P2-12 RDB- P1-17 P2-5 RTA+ P1-12 P2-13 RTB- P1-8 P2-8 P1-5 P1-8 P1-7 P1-1 P1-1 P2-1 Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 301: Nt8D74 Clock Controller To Intergroup Cable

    This cable is available in the following lengths: • NT8D83AC 1.2 m (4 ft) • NT8D83AD 1.8 m (6 ft) Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 302: Nt8D85 Network To Ipe Cable

    This cable connects the PRI/DTI card to the MDF through the I/O connector panel. It is 15.2 m (50 ft) long. Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 303: Nt9J93Ad Pri/Dti Echo Canceller To I/O Cable

    NTND98 PRI to I/O panel cables These cables connect the PRI card to the I/O panel. • NTND98 6 ft Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 304 304 Nonstandard cables Nortel Communication Server 1000 ISDN Primary Rate Interface Installation and Commissioning NN43001-301 02.03 Standard Release 5.5 7 December 2007 Copyright © 2003-2007, Nortel Networks...
  • Page 306: Isdn Primary Rate Interface Installation And Commissioning

    While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.

Table of Contents