Nortel Communication Server 1000S Installation And Configuration Manual page 323

Isdn primary rate interface
Hide thumbs Also See for Communication Server 1000S:
Table of Contents

Advertisement

LD 73 — Defining the 2.0 Mb DTI system timers (Part 2 of 3)
Prompt
Response
MAND
0-(15)-1440
NCSD
0-(15)-1440
1S-59S
OSGD
0-(15)-1440
OOSC
0-(5)-127
PERS
0-(100)-254
DBNC
(10)-32
CCO
xx
<CR>
X
PREF CCO
xx
SREF CCO
xx
CC1
xx
PREF CC1
xx
SREF CC1
xx
CC2
xx
PREF CC2
xx
SREF CC2
xx
CC3
xx
2.0 Mb DTI implementation
Description
Maintenance guard time in minutes.
New call suppression guard time in minutes and seconds.
Out-of-service guard time in minutes.
Out-of-service occurrences since midnight (DTI disabled).
Persistence timer in milliseconds for far-end problems.
Debounce timer in milliseconds.
Card slot number for Clock Controller 0.
No change for defaults.
To remove clock controller data.
Card number of PRI/DTI/SILC containing the primary clock
reference for the main cabinet
Card number of PRI/DTI/SILC containing the primary clock
reference for the main cabinet
Card number for Clock Controller 1.
Primary Reference DTI/PRI loop for Clock controller one.
Primary Reference DTI/PRI loop for Clock controller one.
Card number for Clock Controller 2.
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing
the primary clock reference.
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing
the primary clock reference.
Card number for Clock Controller 3.
ISDN Primary Rate Interface
Page 323 of 394
Installation and Configuration

Advertisement

Table of Contents
loading