LD 14 — Defining service channels and PRI trunks (Part 2 of 2)
Prompt
Response
0-127 1-4000
...
LD 73 — Defining system timers and clock controller parameters (Part 1 of 2)
Prompt
Response
REQ
CHG
TYPE
PRI2
FEAT
SYTI
CCO
xx
PREF CCO
xx
SREF CCO
xx
CC1
xx
PREF CC1
xx
SREF CC1
xx
CC2
xx
PREF CC2
xx
SREF CC2
xx
2.0 Mb PRI implementation
Description
Range for CS 1000M Small System, Meridian 1 Small System,
CS 1000S system, Media Gateway 1000B, and
Media Gateway 1000T.
Description
Change data.
2.0 Mb PRI.
System timers.
Card slot number for Clock Controller 0.
Card number of PRI/DTI/SILC containing the primary clock
reference for the main cabinet
Card number of PRI/DTI/SILC containing the primary clock
reference for the main cabinet
Card number for Clock Controller 1.
Primary Reference DTI/PRI loop for Clock controller one.
Primary Reference DTI/PRI loop for Clock controller one.
Card number for Clock Controller 2.
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing
the primary clock reference.
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing
the primary clock reference.
ISDN Primary Rate Interface