Connect the cables
Figure 87
NTBK50 cabling
Small System
553-3001-201
Standard 2.00
2.0 Mb PRI implementation
Follow the instructions below to connect cables to the NTBK50 PRI card.
Also refer to Figure 87.
In the cabling area, located directly below the card cage, remove the
retaining bar that secures the MDF cables. Connect the NTBK05DA/CA
interface cable to the 50-pin Amphenol connector below the slot in which
the NTBK50 is installed. Re-install the retaining bar to secure the
cable(s) in place.
Terminate the NTBK05DA/CA carrier cable as required.
NTBK50
September 2004
NTBKO5AA
120½ Twisted Pair
NTBKO5CA
75½ Coax Pair
To 2.048
Mpbs Carrier
Cross Connect
553-AAA1073