Nortel Communication Server 1000S Installation And Configuration Manual page 342

Isdn primary rate interface
Hide thumbs Also See for Communication Server 1000S:
Table of Contents

Advertisement

Page 342 of 394
Figure 84
NTAK79 cabling
CS 1000S
553-3001-201
Standard 2.00
2.0 Mb PRI implementation
Procedure 40
Connecting the cables
Follow the instructions below to connect cables to the NTAK79 PRI card. Also
refer to Figure 84.
1
In the cabling area, located directly below the card cage, remove the
retaining bar that secures the MDF cables. Connect the NTBK05DA/CA
interface cable to the 50-pin Amphenol connector below the slot in which
the NTAK79 is installed. Re-install the retaining bar to secure the cable(s)
in place.
2
Terminate the NTBK05DA/CA carrier cable as required.
2 Mb PRI
or
2Mb DTI
September 2004
End of Procedure
NTBKO5DA
120½ Twisted Pair (6.15 m)
NTBKO5CA
75½ Coax Pair (6.15 m)
To 2.048
Mpbs Carrier
Cross Connect
553-AAA1985