DCH Address select switch for NTBK51AA daughter board for
NT5D97AA/AB
553-3001-201
Standard 2.00
NT5D97 Dual-port DTI2/PRI2 installation and removal
Ring ground switches for NT5D97AA/AB
A set of four DIP switches (S2) selects which Ring lines are connected to the
ground. Refer to Table 48 on
Table 42
Ring ground switch settings
Switch
Description
1
Trunk 0 Transit
2
Trunk 0 Receive
3
Trunk 1 Transmit
4
Trunk 1 Receive
In case of an on-board NTBK51AA D-channel daughterboard, a set of four
switches (S3) provide the daughterboard address. Refer to Table 50 on
169.
Note: Switch 8 of S3 (S3-8) does not require a switch setting to select
between the on-board NTBK51AA D-channel daughterboard and an
external DCHI/MSDL. The NT5D97 detects when the on-board
NTBK51AA D-channel daughterboard is used.
Table 43
DCH mode and address switch settings
Switch
Description
1-4
D-channel daughterboard address
5-8
For future use
September 2004
page
169.
S2 switch settingS
OFF-Ring line is not grounded
ON- Ring line is grounded
OFF-Ring line is not grounded
ON- Ring line is grounded
OFF-Ring line is not grounded
ON- Ring line is grounded
OFF-Ring line is not grounded
ON- Ring line is grounded
S3 switch setting
See table
OFF