Nortel Communication Server 1000S Installation And Configuration Manual page 322

Isdn primary rate interface
Hide thumbs Also See for Communication Server 1000S:
Table of Contents

Advertisement

Page 322 of 394
LD 73 — Defining the grade of service timers for the DTI card (Part 2 of 2)
Prompt
Response
SLP
NS mt dt ct ot
GP2
T2 mt dt ct ot
FRFW
YES (NO)
LD 73 — Defining the 2.0 Mb DTI system timers (Part 1 of 3)
Prompt
Response
REQ
NEW
CHG
TYPE
DTI2
FEAT
SYTI
553-3001-201
Standard 2.00
2.0 Mb DTI implementation
Description
Maintenance threshold slip count.
NS = Error count values are in the range 1-255.
mt = Maintenance threshold time (MNT).
dt = No new data calls threshold time (NNDC).
ct = No new calls threshold time (NNC).
ot = Out of service threshold time (OOS).
Group 2 error thresholds.
This is the maximum amount of time that can occur before
software checks the associated thresholds of 120 to 32640
msec and rounds it to the closest multiple of 128 msec. T2
error count values are in the range 1-(20)-255.
NC = Error count values are in the range 1-255.
mt = Maintenance threshold time (MNT).
dt = No new data calls threshold time (NNDC).
ct = No new calls threshold time (NNC).
ot = Out of service threshold time (OOS).
Note: The following requirements must be met for this input:
mt = >dt = >ct = >ot.
This 2.0 Mb DTI card is (is not) equipped with special
Firmware for France.
Description
Add or Change Digital Trunk Interface data block.
2.0 Mb DTI.
Change the switch timers and counters for 2.0 Mb DTI.
There is only one such block per switch.
September 2004

Advertisement

Table of Contents
loading

Table of Contents