Table 30
Cable for the NT8D72 PRI card for Multi Group systems (Part 2 of 2)
QCAD133
I/O Panel
QCAD129
PRI card
RS-232
I/O Panel
RS-232
PRI card
QCAD133
PRI card
RS-232
PRI card
Note 1: Only when primary clock source.
Note 2: Only when secondary clock source.
Note 3: Multi-group junctor board connection.
Note 4: Run to connector on network pack.
Note 5: Run directly to DCHI card.
Note 6: Run by means of cabinet I/O panel to CSU, echo canceller, or cross connect terminal.
Note 7: Run by means of cabinet I/O panel to cross-connect terminal or echo canceller from
non shielded system.
Note 8: No additional cabling is required for multiple PRIs. The D-channel is associated
through software in LD17, prompt PRI.
Table 31
Cable for the QPC720 PRI card for Half and Multi Group systems (Part 1 of 3)
Cable
From
For half group only
QCAD130
QPC720
NT8D79xx
NT8D72 and QPC720 PRI card installation
Patch Panel
J6
I/O Panel
Echo
Canceller
J6
Echo
Canceller
J4
Patch Panel
J6
Echo
Canceller
Des.
Con.
To
J1
QPC471/
QPC775
ISDN Primary Rate Interface
Des.
Con.
Comments
CC-0
J2
Only when primary
clock source.