LD 14 — Assigning a channel identification to each trunk with the ISL option
Prompt
TN
RTMB
CHID
Implement shared mode
LD 17
Prompt
USR
ISLM
LD 16
Prompt
IFC
553-3001-201
Standard 2.00
1.5 Mb ISL implementation
Response
l ch
0-511 1-4000
0-127 1-4000
1-192
The same DTI/PRI software implementation sequence can be used as for
Dedicated mode with the following exceptions:
Response
SHA
1-192
Response
SL1
September 2004
Description
Loop and channel for digital trunks
Route number and Member number
Range for Large System and CS 1000E system.
Range for CS 1000M Small System, Meridian 1 Small
System, CS 1000S system, Media Gateway 1000B,
and Media Gateway 1000T.
Channel identifier for ISL channels (remove with Xnn)
must be coordinated with far-end (no default value).
Description
D-channel for ISL in "shared" mode, used for both
ISDN PRI and ISL.
Number of ISL B-channel (trunks) controlled by the
D-channel (no default value).
Description
Interface type must be SL1 (this is the only type
supported for ISL).