LD 73 — Defining the 2.0 Mb DTI system timers (Part 3 of 3)
Prompt
Response
PREF CC3
xx
SREF CC3
xx
CC4
xx
PREF CC4
xx
CCGD
0-(15)-1440
CCAR
0-(15)
553-3001-201
Standard 2.00
2.0 Mb DTI implementation
Description
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing
the primary clock reference.
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing
the primary clock reference.
Card number for Clock Controller 4.
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing
the primary clock reference.
Clock controller free run guard time in minutes.
Clock controller audit rate. The time, in minutes, between
normal CC audits. Only programmable on units equipped with
2-Mb DTI.
Note 1: The clock controller prompts only appear for clocks
which are valid for the machine type being configured. The
prompts only appear if the system is in a valid state for the
definition of the 2.0 Mb DTI clock controller data that is, the
DTI clock references must be unused or in a free-run mode.
Note 2: Before programming clock controller references, the
QPC775 clock controller card(s) must be plugged in, and the
switches on the system's QPC441 3 Port Extender must be
appropriately set. Otherwise, the PREF and SREF prompts
are not given.