LD 73 — Configuring the D-channel for ISL
Prompt
Response
REQ
NEW
CHG
TYPE
DDB
TRSH
0-15
RALM
1-(3)-128
BIPC
1-(2)-128
LFAC
1-(3)-128
BIPV
1-(3)-4
1-(2)-4
SRTK
1-(5)-24
1-(30)-3600
SRNT
1-(15)1024
1-(3)-1024
LFAL
1-(17)-10240
1-(511)-10240
SRIM
(1)-127
SRMM
1-(2)-127
553-3001-201
Standard 2.00
1.5 Mb ISL implementation
Description
Add new data.
Change existing data.
Digital data block.
Assign a threshold set or table.
Yellow alarm 24-hour threshold.
24-hour bit rate violation threshold.
24-hour loss of frame alignment threshold.
Bit rate (bipolar violation and CRC) monitoring limits for
maintenance and out-of-service thresholds.
Frame slip-tracking-monitoring limits (in hours).
Non-tracking slip-rate monitoring maintenance and out-of-
service thresholds.
Loss of frame alignment monitoring limits.
Slip rate improvement timer.
Maximum number of times the slip rate exceeds the
maintenance limit.