Connect Oscilloscope Probes to Oscilloscope

CH 1
Either the N2819A
Differential Probe (for Gate
OR
Current, I
)
the N2873A
G
Probe (for V
).
CLAMP
See table below.
Figure 3
Oscilloscope Probe Connections
Oscilloscope
Color
Channel
1
1
Yellow
Green
2
Blue
3
Red
4
1 Only one of these two probes should be used in a DPT test. The N2819A Differential Probe is used when measuring Gate Current and Gate
Charge. The standard N2873A probe is used with the Clamp Test Module to measure V
2 Use the 0.56 N-m (5 lb-in) 5/16 in. SMA Break-over torque wrench (provided with the PD1500A system) to tighten the SMA cable connector
to the PD1000-60002 Protection Probe. Failure to do so might cause extensive ringing in the DPT measurements. See appendix for details.
88
CH 2
PD1000-60002
2
Protection Probe
and cable to Coaxial Shunt
(Source Current, I
/I
D
Oscilloscope Probe
N2819A Differential Probe
Standard N2873A Probe
PD1000-60002 Protection Probe
2
and cable to Coaxial Shunt
Standard N2873A Probe
High Voltage 10076C Probe
Keysight Double-Pulse Test Rack And Safety Enclosure Installation Guide
Connect Oscilloscope Probes to Oscilloscope
CH 3
N2873A Probe
Control Signal
(Gate Voltage,
)
V
/V
)
C
GS
GE
Used to Measure
Gate Current, I
G
Clamp voltage, V
CLAMP
Source Current, I
D
Gate Voltage, V
/V
GS
Drain/Collector Voltage,
V
/V
DS
CE
CLAMP
Ch 4
10076C High Voltage
Probe, V
/V
DS
CE
Connects to Test
Module
Gate Driver Module
Clamp Module
/I
Coaxial Shunt on
C
DUT Module
Gate Driver Module
GE
DUT Module
.