Sign In
Upload
Manuals
Brands
Emerson Manuals
Scanner
PACSystems Versamax
Emerson PACSystems Versamax Manuals
Manuals and User Guides for Emerson PACSystems Versamax. We have
3
Emerson PACSystems Versamax manuals available for free PDF download: User Manual, Important Product Information
Emerson PACSystems Versamax User Manual (129 pages)
GENIUS NETWORK INTERFACE UNIT
Brand:
Emerson
| Category:
I/O Systems
| Size: 2 MB
Table of Contents
Table of Contents
2
Introduction
7
Related Manuals
7
The Versamax TM Family of Products
8
The Versamax Genius I/O Station
9
Versamax I/O in a Genius System
10
The Genius NIU
11
Genius NIU Specifications
12
Genius NIU Compatibility
12
Power Supplies
13
Versamax Modules
14
Carriers
17
Expansion Modules
19
Versamax General Product Specifications
21
Installation
23
Module Clearance
24
Thermal Considerations
25
Mounting Instructions
26
Removing the NIU from the DIN Rail
27
Panel-Mounting
28
Installing an Expansion Transmitter Module
29
Removing an Expansion Transmitter Module
30
Installing an Expansion Receiver Module
30
Removing an Expansion Receiver Module
31
Expansion Rack Power Sources
31
Connecting the Expansion Cable: RS-485 Differential
32
Connecting the Expansion Cable: Single-Ended
34
Installing Power Supply Modules
35
Installing Additional Modules
37
Setting the SBA and Baud Rate
39
Selecting a Baud Rate
40
Special Switch Settings on the NIU
41
Using a Network Serial Bus Address
41
Using the Network Baud Rate
42
Overriding a Network Configuration
43
Re-Enabling Network Configuration
43
Selecting a Cable Type
44
Using Other Cable Types
46
Bus Length
47
Making Bus Connections
47
Terminating a Bus
48
Lightning Transient Suppression
48
Observing the Leds
50
CE Mark Installation Requirements
51
Operation
52
NIU Data Memories
52
Scanning Inputs and Outputs in the I/O Station
53
Data Transfer between the NIU and the Genius Bus
53
Communications on the Genius Bus
54
Input Data Format
55
Output Data Format
56
Genius Bus Scan Time
57
Fault Transfer Times
59
Operation of the Genius NIU in Enhanced Diagnostics Mode
60
Input Message Times for Enhanced Diagnostics Mode
62
GNIU Sweep Times for Enhanced Diagnostics Mode
63
Configuration
66
Station Racks and Slots
67
Autoconfiguration or Programmer Configuration
68
Autoconfiguration
68
Programmer Configuration
68
Programmer Configuration of the Genius NIU and I/O Station
69
Notes on Programmer Configurations for the I/O Station
69
Basic Steps for Programmer Configuration
69
Create a New Versamax Genius Target
70
Configure the Type of Expansion Racks
71
Adding Expansion Racks
73
Configure the Power Supplies
73
Configure the Genius NIU
74
Configuring I/O References
79
Configuring Carriers and Modules
80
Programmer Configuration: Download, Upload, Verify, Clear
81
Autoconfiguration of the Genius NIU and I/O Station
84
Autoconfiguration Sequence
84
Autoconfiguration Assigns Reference Addresses
85
Adding I/O Modules to an Autoconfigured I/O Station
85
Clearing an Autoconfiguration
85
Hot Inserting, I/O Modules
86
Autoconfiguring an I/O Station with Expansion Racks
86
How Autoconfiguration Handles Equipment Changes
87
Datagrams
88
Datagram Types
89
Read Map
89
Read Map Reply
90
Report Fault Datagram Format
91
Configuration Data
93
Read Configuration Data
94
Read Configuration Reply Data
94
Write Configuration Data
95
Configuration Data Formats
96
Set NIU Operating Mode
111
Redundancy
113
Cpu/Bus Controller Redundancy
113
Hot Standby CPU Redundancy
114
Duplex CPU Redundancy
114
Using the NIU in a Genius Bus Redundancy System
115
Redundant Bus Configurations
116
Appendix A: Operation of the Genius Bus
118
Electrical Interface
118
Serial Bus Waveforms
120
Maximum Bus Length
121
A-3.1 Attenuation
121
A-3.2 Distortion
121
A-3.3 Propagation Delay
123
Serial Data Format
123
A-4.1 Bus Access
123
Genius Transceiver Electrical Specification
125
Bus Errors
125
Appendix B: Performance Data
126
General Contact Information
129
Technical Support
129
Advertisement
Emerson PACSystems Versamax User Manual (53 pages)
PROFINET SCANNER
Brand:
Emerson
| Category:
Scanner
| Size: 1 MB
Table of Contents
Table of Contents
2
Chapter 1: Introduction
5
Versamax PROFINET Scanner Overview
5
Versamax PROFINET Scanner Versions
6
Versamax PROFINET Scanner Specifications
7
Versamax PROFINET Scanner Controls and Indicators
8
Versamax PROFINET Scanner Leds
8
Power Supply Modules
10
Ethernet Network Ports
11
USB Port
13
Compatible Versamax Modules, Carriers, and Power Supplies
13
Chapter 2: Installation
18
Module Installation
18
Cable and Connector Clearance Requirements
19
General Installation Requirements
20
Installation in Hazardous Areas
20
ATEX Marking
21
Installing the Module on a DIN Rail
21
Removing the Module from the DIN Rail
21
Installing Power Supplies
23
PROFINET Scanner Power-Up and Restart
24
LED Operation
24
Special LED Blink Patterns
25
Firmware Updates
26
Firmware Update for Modules in the Remote Node
27
Chapter 3: Configuration
29
Configuration Overview
29
Basic Configuration Steps
29
Configuration Tool
30
Adding a Versamax PROFINET Scanner to a LAN
30
Configuring Versamax PROFINET Scanner Parameters
30
Adding Versamax PROFINET Scanner Power Supplies
31
Adding Versamax Modules to a Remote Node
32
Adding Power Supplies between Modules
32
Configuring Versamax Module Parameters
32
Configuring Analog Modules that Have Jumpers
34
Assigning IO-Device Names
36
After the Configuration Is Stored to the IO-Controller
37
Output Operation
37
Clearing the IO-Controller Configuration
38
Replacing PROFINET Scanner Hardware
39
Chapter 4: Diagnostics
40
PROFINET Scanner Status and Control Data
40
Output Control Bits
40
Input Status Bits
41
Error Handling
41
Fatal Error Handling
42
PROFINET Alarms
42
Clearing Faults on Versamax Analog Modules
45
PROFINET Module Loss, Add & Mismatch Faults
46
Diagnostics for BEM003 PROFIBUS DP Networks
47
Chapter 5: Maintenance Mode
48
Entering Maintenance Mode and Performing Maintenance
49
Exiting Maintenance Mode and Restoring Operation
49
Maintenance Mode Retentiveness through Power Cycle
50
Appendix A: PROFINET Specifications
51
PROFINET Protocol Support
51
Technical Data
51
Limitations
52
Emerson PACSystems Versamax Important Product Information (11 pages)
ETHERNET NETWORK INTERFACE UNIT ENIU
Brand:
Emerson
| Category:
Recording Equipment
| Size: 0 MB
Table of Contents
Specifications
3
Pre-Installation Check
3
Product Revision History
4
Operating Notes
4
Open Issues
6
Installation in Hazardous Locations
9
Panel Mounting
9
Bus Connector
10
Ethernet MAC Address
10
Advertisement
Advertisement
Related Products
Emerson PACSystems Advanced PROFINET Scanner
Emerson PACSystems
Emerson PACSystems RSTi-EP
Emerson PaCSystems VersaMax Series
Emerson PACSystems RXi Series
Emerson PACSystems RXi
Emerson PACSystems RXi Panel PC
Emerson PACSystems RXi Web panel
Emerson PACSystems RXi Industrial Monitor
Emerson PACSystems RX3i Energy Pack
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL