Drain Water From Fuel Filter/Water Separator - Sd-116, -122 (155 Hp Electronic Engine) - Volvo Ingersoll Rand SD-116 TF Series Operator's Manual

Table of Contents

Advertisement

SECTION 5
Drain Water from Fuel Filter/Water Separator - SD-116, -122 (155 HP Electronic
Engine)
Filter/water separator (Figure 5-22) must be drained of accumulated water and sediment daily.
To drain the water follow the steps listed below.
1. Park machine on stable, level surface and shut down engine.
2. Open the hood.
3. Open the containment drain valve (1, Figure 5-22) by turning counterclockwise
sufficiently to allow contaminants and water to drain. If more than 59 mL (2
ounces) are removed, the fuel filter must be refilled with fuel.
4. Close the drain valve.
5-24
MAINTENANCE INSTRUCTIONS
Figure 5-22
SD-116F/DX/122D/F/DX/160F/DX/190DX/200F/DX