Grease the Ratchet Jack

1. Open the battery access door (1, Figure 5-65).
2. Grease the ratchet jack (2, Figure 5-65) by greasing the fitting (3). Refer to
Section 8 for oil specifications.
3. Close the battery access door.

Check Cooling System Integrity

1. Park the machine on a level surface and shut off engine.
2. Verify coolant level is normal for engine temperature.
3. Inspect radiator and oil cooler hoses for leaks.
4. Inspect radiator cap for leaks.
5. Check drain petcock and attached hose for condition.
6. Inspect radiator, fan and belts for damage.
7. Check if water temperature gauge is operating.