Change Eccentric Oil - Volvo Ingersoll Rand SD-116 TF Series Operator's Manual

Table of Contents

Advertisement

MAINTENANCE INSTRUCTIONS
8. Fill the axle transfer case with oil through fill/level hole (1, Figure 5-73) until oil
is level with the bottom of the fill/level hole. Refer to Section 8 Fuel & Lubricant
Specifications for details.
9. Clean, replacement tighten level plug.
10. Run the machine and check for leaks.

Change Eccentric Oil

Hot oil or components can burn.
Oil must be at normal operating temperature when draining.
Avoid contact with hot oil or components.
Do not allow oil to drain into the ground.
1. Allow eccentric oil to reach operating temperature and park the machine on a
level surface with the drum index, angle mounted on the inside of the drum, at
the 12 o'clock position.
NOTE: This positioning will place the eccentric fill plug (1, Figure 5-74) in the
12 o'clock position. This will also bottom-out the drain plug (2) In the 6 o'clock
position and the level indicator gauge (3) in the 4 o'clock, level-read position.
SD-116F/DX/122D/F/DX/160F/DX/190DX/200F/DX
WARNING
!
Figure 5-74
SECTION 5
5-63

Advertisement

Table of Contents
loading

Table of Contents