MAINTENANCE INSTRUCTIONS
2. Clean the inside of the air cleaner (2, Figure 5-9).
3. Pull the safety air cleaner element (1, Figure 5-10) out of the housing.
4. Examine the safety air cleaner element and replace if:
Torn or perforated pleats are present.
Records indicate the primary element has been replaced three times or 1 year
duration has passed since the last replacement.
5. Carefully install the replacement safety element (1, Figure 5-10) by pushing it
straight into housing.
6. Carefully install the cleaned or replacement primary element (1, Figure 5-9).
7. Ensure the evacuator valve (3, Figure 5-11) is clear.
8. Install air cleaner cover (2, Figure 5-11) and secure with clip (1). Ensure clip is
tight.