Torque Loose Bolted Connections; Check All Shock Mounts; 10 Hour Or Daily Routine Maintenance; Check Engine Oil Level - Volvo Ingersoll Rand SD-116 TF Series Operator's Manual

Table of Contents

Advertisement

SECTION 5
5. Check air cleaner mounting hardware for security and correct as required.
6. Check all hoses for cracks, chafing, or deterioration, and replace at the first sign
of probable failure.

Torque Loose Bolted Connections

1. Properly torque all loose nuts or bolts found during the daily inspection. Refer
to Section 9.
2. Replace self locking nuts if they have been loosened.

Check All Shock Mounts

1. Check all shock mounts (1, Figure 5-14) periodically for looseness or
deterioration.
2. Replace shock mounts (one at a time) that have torn or excessively cracked
rubber. Torque all capscrews and nuts as necessary.

10 HOUR OR DAILY ROUTINE MAINTENANCE

Check Engine Oil Level

1. Park machine on stable, level surface and shut down engine.
2. Wait at least ten minutes for the engine to cool following shutdown.
3. Remove dipstick (1, Figure 5-15 for Tier 2 engines; Figure 5-16 for Tier 3
engines) and wipe it clean with a lint-free, dry cloth. Push dipstick back into
engine.
5-18
MAINTENANCE INSTRUCTIONS
Figure 5-14
SD-116F/DX/122D/F/DX/160F/DX/190DX/200F/DX

Advertisement

Table of Contents
loading

Table of Contents