Volvo Ingersoll Rand SD-116 TF Series Operator's Manual page 74

Table of Contents

Advertisement

SECTION 4
Starting aids are extremely flammable and can explode.
Overloading the engine intake system could result in an explosion.
Avoid overloading the engineer intake system with starting aids.
Starter may overheat if operated longer than 30 seconds. If the engine
fails to start, allow the starter to cool 2 to 3 minutes before trying again.
5. Turn ignition switch (12, Figure 4-12) to the START
engine starts, release switch immediately, and it will return to the ON position.
NOTE: Start the engine and run it a short time, to warm up the engine and
hydraulic systems, but do not run engine at idling speed for more than 10
minutes.
6. Verify that the indicator lights turn off after the engine has started. If lights
remain on, shut down the engine and have the fault(s) corrected before
continuing operation.
7. Check for the correct operation of the steering system with the engine running.
Turn the steering wheel fully to the left and then to the right. The movement of
the steering should be smooth and without hesitation. If not, do not operate the
machine until the condition is corrected.
8. With engine running, release the parking brake control
and ensure Brake Light goes out. Observe area around machine for personnel/
obstructions. If the machine is equipped with a back-up alarm, move propulsion
control
operational. Alarm should sound even before machine begins movement.
Return propulsion control to STOP position. If alarm is not operational or does
not sound immediately, do not operate the machine until the condition is
corrected.
9. Check for correct operation of brake systems by driving the machine in forward
and reverse directions using propulsion control
alternately accelerate and brake machine movement. Return propulsion control
to STOP position. If brake system is not operating properly, do not operate the
machine until the condition is corrected.
4-10
WARNING
!
NOTICE
(19, Figure 4-11) in reverse direction to check that alarm is
OPERATING INSTRUCTIONS
position. Once the
(15, Figure 4-12)
(19, Figure 4-13) to
SD-116F/DX/122D/F/DX/160F/DX/190DX/200F/DX

Advertisement

Table of Contents
loading

Table of Contents