MAINTENANCE INSTRUCTIONS
Raw, unfiltered air can cause engine damage.
Never service the air cleaner while the engine is running.
1. Open clip (1, Figure 5-4) and remove air filter housing cover (2) to access the
filter elements. Check evacuator valve (3) to see that it is not inverted,
damaged or plugged.
TIER II ENGINES
2. Gently remove primary filter element (1, Figure 5-5).
SD-116F/DX/122D/F/DX/160F/DX/190DX/200F/DX
CAUTION
!
Figure 5-4
Figure 5-5
TIER III ENGINES
SECTION 5
5-11